Location Of Controls And Components; Indoor Unit - Panasonic WH-SXC09F3E8 Service Manual

Air-to-water heat pump
Hide thumbs Also See for WH-SXC09F3E8:
Table of Contents

Advertisement

4. Location of Controls and Components

4.1

Indoor Unit

4.1.1
Location of Control
 Control Panel
9
10
11 12
8
7
5
AUTO
HEAT
MON TUE WED THU FRI SAT SUN
4
COOL
ON
TANK
OFF
3
HEATER
FORCE
OPERATION
2
1
1
13
15
14
15
16
2
16
17
17
6
ACTUAL
3
18
18
HEATER
hr
BOOSTER
19
19
°C
QUIET
kwh
SETTING
4
hr
STATUS
°C
SERVICE
20
20
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
OFF/ON Button
This button starts or stops the mode operation function of the unit.
Operation LED
This LED indicates the unit is in operation.
External Thermo Controller Connected Display
This LCD show the external thermo controller connected display.
Force Heater Request OFF/ON Indicator
This icon indicates force heater request OFF/ON mode operation.
Backup Heater Enabled/Disabled Indicator
This icon indicates backup heater enabled/disabled mode operation.
Quiet Mode Indicator
This icon indicates quiet mode operation.
Tank Mode Indicator
This icon indicates tank mode operation.
Cool Mode OFF/ON Indicator
This icon indicates cooling mode OFF/ON operation.
Heat Mode OFF/ON Indicator
This icon indicates heating mode OFF/ON operation.
Auto Mode OFF/ON Indicator
This icon indicates auto mode OFF/ON operation.
Solar Display
This LCD show the solar display.
Caution (Tank Temperature above 60°C) Indicator
This LCD show the Caution display.
Timer/Clock Setting Display
This LCD show the weekly schedule timer setting and clock display.
Outdoor Ambient Temperature Display
This LCD show the outdoor ambient temperature.
Water Outlet Temperature Display
This LCD show the water outlet temperature.
Backup Heater Actual (OFF/ON) Indicator
This icon indicates backup heater actual (OFF/ON) operation.
Booster Heater Actual (OFF/ON) Indicator
This icon indicates booster heater actual (OFF/ON) operation.
System Setting Mode OFF/ON Indicator
This icon indicates the system setting mode request OFF/ON display.
System Status Check Mode OFF/ON Indicator
This icon indicates the status check mode request OFF/ON display.
System Service Mode OFF/ON Indicator
This icon indicates the system service mode request OFF/ON display.
15
Water pressure gauge
• Do not press or hit the glass cover using hard
and sharp objects. Failure to do so may cause
damage to the unit.
• Ensure that the water pressure is between 0.05
and 0.3 MPa (0.1 MPa = 1 bar).
• In case the water pressure is out of the above
range, consult an authorised dealer.
 