1.4 Service position

This unit has been designed so that the Mechanism and
Main board assemblies can be removed together from the
chassis assembly. Before diagnosing or servicing the cir-
cuit boards, take out the major parts from the chassis as-
sembly.
1.4.1 How to set the "Service position"
(1) Refer to the disassembly procedure and perform the dis-
assembly of the major parts before removing the Drum
assembly.
(2) Lower the cassette holder to prepare for the removal of
the Mechanism assembly screws. (Refer to the "Proce-
dures for lowering the Cassette holder assembly" of 1.3
Disassembly/assembly method.)
(3) Remove the combined Mechanism and Main board as-
semblies.
(4) Connect the wires and connectors of the major parts that
have been removed in step (1). (Refer to Fig.1-4-1a.)
(5) Place the combined Mechanism and Main board assem-
blies upside down.
(6) Insert the power cord plug into the power outlet and then
proceed with the diagnostics and servicing of the board
assembly.
Notes:
• Before inserting the power cord plug into the power
outlet, make sure that none of the electrical parts are
able to short-circuit between the workbench and the
board assembly.
• For the disassembly procedure of the major parts and
details of the precautions to be taken, see "1.3 Disas-
sembly/assembly method".
• If there are wire connections from the Main board and
Mechanism assemblies to the other major parts, be
sure to remove them ( including wires connected to the
major parts ) first before performing step (2).
• When carrying out diagnosis and repair of the Main
board assembly in the "Service position", be sure to
ground both the Main board and Mechanism assem-
blies. If they are improperly grounded, there may be
noise on the playback picture or FDP counter display
may move even when the mechanism is kept in an in-
operative status.
• In order to diagnose the playback or recording of the
cassette tape, set the Mechanism assembly to the re-
quired mode before placing it upside down. If the
mechanism mode is changed (including ejection) while
it is in an upside down position the tape inside may
be damaged.
• The mechanism and board assemblies of this unit are
attached by connectors only.
When carrying out a diagnosis or repair of the boards
in the "Service position", make sure that the connec-
tors are not disconnected.
1-4
TP2253
A.PB.FM
[VR620/77,
TP106
VR625/77]
PB.FM
C3018
Timer clock
TP111
TP4001
TPGND
D.FF
CTL.P
Fig. 1-4-1a

1.5 Mechanism service mode

This model has a unique function to enter the mechanism
into every operation mode without loading of any cassette
tape. This function is called the "Mechanism service mode".
1.5.1 How to set the "Mechanism service mode"
(1) Unplug the power cord plug from the power outlet.
(2) Connect TPGND and TP7001(TEST) on the Main board
assembly with a jump wire.
(3) Insert the power cord plug into the power outlet.
(4) With lock levers (A) (B) on the left and right of the Cas-
sette holder assembly pulled toward the front, slide the
holder in the same direction as the cassette insertion di-
rection. (For the positions of lock levers (A) (B), refer to
the "Procedures for lowering the Cassette holder assem-
bly" of 1.3 Disassembly/assembly method.)
(5) The cassette holder lowers and, when the loading has
completed, the mechanism enters the desired mode.
1.6

Jig RCU mode

This unit uses the following two modes for receiving remote
control codes.
1) User RCU mode : Ordinary mode for use by the user.
2) Jig RCU mode
: Mode for use in production and serv-
icing.
When using the Jig RCU, it is required to set the VCR to
the Jig RCU mode (the mode in which codes from the Jig
RCU can be received). As both of the above two modes
are stored in the EEPROM, it is required to set the VCR
back to the User RCU mode each time that an adjustment
is made or to check that the necessary operations have
been completed. These modes can be set by the opera-
tions described below.
1.6.1 Setting the Jig RCU mode
(1) Unplug the power cord plug from the power outlet.
(2) Press and hold the "REC" and "PAUSE" buttons on the
VCR simultaneously, while plugging the power cord plug
into the power outlet.
When the VCR is set to the Jig RCU mode, the symbols
( " : " ) in the time display of the FDP are turned off.
1.6.2 Setting the User RCU mode
(1) Turn off the power.
(2) Press the "REC" and "PAUSE" buttons of the VCR si-
multaneously. Alternatively, transmit the code "80" from
the Jig RCU.
Main board
assembly
CP4001
CN7001
CP5302
[VR620/77, VR625/77]
To Mini front board
assembly
TP7001
[VR620/77, VR625/77]
TEST