Global Subsystem - TDK-Lambada Z10-20 User Manual

Z+series programmable dc power supplies 200w/400w/600w/800w built-in usb, rs-232 & rs-485 interface
Table of Contents

Advertisement

WAVE:STEP
WAVE:STEP AUTO - When triggered, creates waveforms consecutively, until the wave is completed.
WAVE:STEP ONCE - When triggered, it executes one step from the list.
SCPI Command Syntax
Example
Query Syntax
Returned Parameters
WAVE:STORe
Stores Voltage or Current, Time, STEP parameter and counter values to specific location in the
memory defined by numbers <1..4>.
SCPI Command Syntax
Example
WAVE:TIME
Sets the slope time of the waveform.
SCPI Command Syntax
Range
Default Suffix
Examples
Query Syntax
Returned Parameters
WAVE:VOLTage
Specifies the output voltage points in a waveform list.
SCPI Command Syntax
Default Suffix
Examples
Query Syntax
Returned Parameters

7.12.13 Global Subsystem

Global Commands General
Power supplies acting upon Global Commands need not be a currently addressed supply.
All power supplies attached to the Interface must be capable of accepting Global Commands.
No messages, OPC or Not Busy will be returned to the HOST PC after a Global Command has
been issued. The Busy Bit of the Status Byte will be set to 0 after this command is issued.
It will be the responsibility of the User Software to add a 20mS delay after each Global Command
is issued and before any other command can be issued.
[SOURce]WAVE:STEP <CRD>
WAVE:STEP AUTO
[SOURce]:WAVE:STEP?
AUTO | ONCE
[SOURce]WAVE:STORe<NF1>
WAVE:STORe 3
[SOURce]:WAVE:TIME <NRf1> {,<NRf1>}
0.001 to 129,600 seconds
S
WAVE:TIME .6,1.5,1.5,.4
WAVE:TIME?
.6,1.5,1.5,.4
[SOURce]:WAVE:VOLTage <NRf+> {,<NRf+>}
V
WAVE:VOLT 2.5,3.0,3.5 WAVE:VOLT MAX,2.5,MIN
WAVE:VOLT?
MAX,2.5,MIN
114
up to 12 parameters
up to 12 parameters

Hide quick links:

Advertisement

Table of Contents
loading