7.12.2 Instrument Subsystem

The subsystem programs one or more power supplies. <NR1> from 1 to 31.
INSTrument:COUPle
SCPI Command Syntax
GEN Command Syntax
Parameters
INSTrument:NSELect
SCPI Command Syntax
GEN Command Syntax
Examples
Query Syntax

7.12.3 Voltage Subsystem

VOLTage
Sets the output voltage value in Volts. The range of voltage values are described in Table 7-5. The
maximum number of characters is 12.
SCPI Command Syntax
GEN Command Syntax
Default Suffix
*RST Value
Examples
Query Syntax
Returned Parameters
VOLTage:MODE
This command selects FIX, LIST, WAVE subsystems control over the power supply output voltage.
SCPI Command Syntax
GEN Command Syntax
Parameters
*RST Value
Examples
Query Syntax
Returned Parameters
INSTrument:COUPle <CRD>
None
ALL|NONE
INSTrument:NSELect <NRf>
ADR n (single address)
INSTrument:NSELect 6
INSTrument:NSELect?
[SOURce]:VOLTage[:LEVel] [:IMMediate][:AMPLitude] <NRf+>
PV < NRf+> PV?
V
0
:VOLT 500 MV
VOLT:LEV 234.56789
[SOURce]:VOLTage[:LEVel][:IMMediate][:AMPLitude]?
VOLTage? MAX VOLTage? MIN
<NR3> VOLT? returns the present programmed voltage level.
VOLT? MAX and VOLT? MIN returns the maximum and minimum programmable
voltage levels.
[SOURce]:VOLTage:MODE <CRD>
None
NONE | FIXed | LIST | WAVE
NONE
VOLT:MODE LIST VOLT:MODE FIX
[SOURce]:VOLTage:MODE?
NONE | FIX | LIST | WAVE
102

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents