1-10. TEMPERATURE PROBE (Continued)
Step 3
Step 5

1-11. DRAWER GASKET

Step 2
1-8
3. Using a flat blade screwdriver, pry the rubber strain
relief from the liner.
4. Pull the probe wires out of the unit, far enough to
access the connector, incased in a protective cover.
5. Cut the wire ties on the ends of the cover and slide the
protective cover up and out of the way.
6. Disconnect the wires at the connector.
7. Reconnect the new temperature probe assembly to the
unit and pull protective cover back over the
connector, then secure with wire ties.
8. Thread the wire back through the hole and push the
strain relief back into the liner.
9. Place drawer back into unit and the unit is now ready
for use.
1. Remove the drawer from the unit.
2. Using a Phillips-head screwdriver, remove the drawer
handle by removing the two screws fastening the
handle to the drawer.