Model CF-941 SECTION 1. MAINTENANCE 1-1. INTRODUCTION This section provides procedures for checking and replacement of the various parts used within the cabinet. 1-2. SAFETY Where information is of particular importance or is safety related, the words NOTICE, CAUTION, or WARNING are used.
Model CF-941 1-3. TEST INSTRUMENTS You may use two test instruments to check the electrical components. 1. A continuity light. 2. An ohmmeter. When the manual refers to the circuit being closed, the continuity light will be illuminated or the ohmmeter should read zero unless otherwise noted.
Model CF-941 1-5. CONTROL BOARD 1. Disconnect the electrical supply to the cabinet. To avoid electrical shock or property damage, move the POWER switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle. 2. Remove the two screws on the front of the control panel and pull control drawer out.
Model CF-941 1-6. POWER SWITCH (Continued) 4. Squeeze the tabs on the back of the switch and pull the switch out from the front of the panel. 5. Install new switch in reverse order. Step 4 1-7. TRANSFORMER 1. Disconnect the electrical supply to the cabinet.
Model CF-941 1-8. RELAYS 1. Disconnect the electrical supply to the cabinet. To avoid electrical shock or property damage, move the POWER switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle. 2. Remove the two screws on the front of the control panel and pull control panel out.
Model CF-941 1-8. RELAYS (Continued) Replacement: 6. Remove power supplied to unit. 7. Label and remove wires from the appropriate relay. 8. Using a Phillips head screwdriver, remove the screws securing the relay and remove the relay from the unit.
Model CF-941 1-9. HEATING ELEMENTS (Continued) 5. Using a Phillips head screwdriver, remove the two screws securing the element to the back of the liner. Step 5 6. Pull the element out towards you until the terminals are exposed. 7. Pull the wires off of the terminals and remove element from the unit.
Model CF-941 1-10. TEMPERATURE PROBE (Continued) 3. Using a flat blade screwdriver, pry the rubber strain relief from the liner. Step 3 4. Pull the probe wires out of the unit, far enough to access the connector, incased in a protective cover.
Model CF-941 1-11. DRAWER GASKET (Continued) 3. Using a Phillips head screwdriver, remove the six screws that secure the backing plate and gasket to the drawer front. 4. Separate the drawer frame from the drawer front. 5. Remove the gasket from the drawer front.
Page 15
0 TO 3 YEARS: During this time, any frypot that fails due to manufacturing or workmanship issues will be replaced at no charge for parts, labor, or freight. Henny Penny will either install a new frypot at no cost or provide a new or reconditioned replacement fryer at no cost.
2-5. DELIVERY Commonly replaced items are stocked by your independent Henny Penny distributor and will be sent out when your order is received. Other parts will be ordered by the distributor from Henny Penny Corporation.
Page 17
Model CF-941 Figure 2-1. Drawer and Shell 1205...
Page 18
Model CF-941 FIG. & PART ITEM NO. DESCRIPTION Qty. DRAWER AND SHELL SC01-034 SCREW 54432 PANEL - RH ACCESS 51545 CONTROL PANEL STUD ASSY. 51562 DECAL - CONTROL √ 5 43768 POWER SWITCH √ 6 51718 GASKET - DRAWER 52668 DRAWER ASSY.- NO VENT...
Page 19
Model CF-941 Figure 2-2. Heater and High Limit...
Page 20
Model CF-941 FIG. & PART ITEM NO. DESCRIPTION Qty. HEATER AND HIGH LIMIT √ 1 18201 HIGH LIMIT - 335º F (BEHIND HEATER PLATE) NS02-005 54538 LINER WELD ASSY. √ 4 14113 BEARING KIT 51951 BRACKET – HEATER (BEFORE SN: GA0407031)