Premaintenance
Procedures
Raising the Mower for Access
The front of the mower can be raised and supported on its
back for access under the machine for maintenance.
1. Raise the platform. Refer to Operating the Platform in
Operation.
2. Remove the battery.
Figure 34
1. Wing nut
2. Battery cover
3. Negative battery cable
3. Drain the fuel from the fuel tank. Refer to Draining
the Fuel Tank in Maintenance.
4. Remove the cap of the hydraulic tank and place a piece
of plastic over the opening and install the hydraulic cap.
This will seal the hydraulic tank and prevent it from
leaking out.
g018098
4. Positive battery cable
5. Battery
1. Cap
2. Piece of plastic
5. With two people, raise the front of the mower so it rests
on the drive tires and the platform in the up position.
6. Perform any maintenance on the machine.
7. With two people, lower the front of the mower to the
ground.
8. Remove the plastic under the hydraulic tank cap.
9. Install the battery for the machine.
28
g017900
Figure 35
3. Hydraulic tank