List of parameterizable operating data (Order codes A
Operating data acc. to default setting
Order codes: A
7 7
... E
7 7
Sensor
Thermocouples
Type
Temperature range
B: Pt30 %Rh/Pt6 %Rh
0 ... 1820 °C
C:W5 %Re
0 ... 2300 °C
D:W3 %Re
0 ... 2300 °C
E:NiCr/CuNi
-200 ... +1000 °C
J:Fe/CuNi (IEC)
-210 ... +1200 °C
K:NiCr/Ni
-200 ... +1372 °C
L: Fe/CuNi (DIN)
-200 ... +900 °C
N:NiCrSi/NiSi
-200 ... +1300 °C
R:Pt13 %Rh/Pt
-50 ... +1760 °C
S:Pt10 %Rh/Pt
-50 ... +1760 °C
T:Cu/CuNi (IEC)
-200 ... +400 °C
U:Cu/CuNi (DIN)
-200 ... +600 °C
Resistance thermometer
(or max. permissible line resistance see
„Technical specifications")
Pt100 (DIN IEC)
-200 ... +850 °C
Pt100 (JIS)
-200 ... +649 °C
Ni100 (DIN)
-60 ... +250 °C
Resistance-based sensors, potentiome-
ters
(or max. permissible line resistance see
„Technical specifications")
mV, V and µA, mA sensors
9)
1)
n = number of thermocouple elements to be connected in series
2)
See „Circuit diagrams" for meaning of type circuit
3)
Line resistance of channels 1 and 2, for max. permissible line resistance see
„Technical specifications" (only with C32, not with C33 and C34)
4)
n = number of resistance thermometers to be connected in series
5)
1/n = number of resistance thermometers to be connected in parallel
6)
Combination of series and parallel connection of resistance thermometers
7)
Operating data: see „Special operating data"
8)
This range does not apply to mean-value and difference circuits.
9)
The max. permissible currents and voltages according to conformity cer-
tificate must be observed in devices with explosion protection.
10)
Without detection of line breakage
© Siemens AG 2009
SITRANS T measuring instruments for temperature
+ B
7 7
Order No. with Order code: 7NG3242 -
7 7 7
+
Connection
A 0 0 Standard
1)
A 0 1 Sum n
n = 2
A 0 2
...
A 0 3
n = 10 B 1 0
2)
A 0 4 Difference
Diff1
A 0 5
Diff2
2)
A 0 6 Mean-val.
MW
A 0 7
A 0 8
A 0 9
A 1 0
A 1 1
Connection
A 2 0 Standard
4)
A 2 1 Sum n
n = 2
A 2 2
...
n = 10 B 1 0
5)
n = 0.1 B 2 1
Parallel n
n= 0.2 B 2 2
n= 0.5 B 2 5
6) 7)
Special value
2)
Difference
Diff1
Diff2
2)
Mean-val.
MW
Connection
A 3 0 Standard
2)
Difference
Diff1
Diff2
2)
Mean val.
MW
A 4 0 Meas. range with Order No.
Transmitters for rail mounting
four-wire system, universal, HART
... E
)
7 7
7 7
7 7 7 7 7
-Z Y01
7 7 7
7 7 7
+
Cold junction
compensation
B 0 1 None
C 0 0
B 0 2 Internal
C 1 0
. . . Fixed val.
0
C 2 0
°C
20
C 2 2
°C
B 3 1
50
C 2 5
°C
B 3 2
60
C 2 6
°C
B 4 1
70
C 2 7
°C
7)
Special value
Y 1 0
External meas.
Y 1 1
(through Pt100
7)
DIN IEC 751)
Connection
Line resis-
tance
C 3 2 0 Ω
B 0 1 2-wire-system
C 3 3 10 Ω
B 0 2 3-wire-system
C 3 4 20 Ω
. . . 4-wire-system
50 Ω
Special val.
Y 0 0
B 5 1
B 5 2
B 6 1
Connection
Line resis-
tance
C 3 2 0 Ω
B 0 1 2-wire-system
C 3 3 10 Ω
B 5 1 3-wire-system
C 3 4 20 Ω
B 5 2 4-wire-system
50 Ω
B 6 1
Special val.
7NG 3242 -
7 7 7 7 7
-Z Y01
0
1
2
3
4
5
6
7
8
SITRANS TW
7 7 7
7 7 7
+
+
Measuring
ranges
-30 ... +60 °C
E
-20 ... +20 °C
E
0 ... 40 °C
E
0 ... 60 °C
E
0 ... 80 °C
E
0 ... 100 °C
E
0 ... 120 °C
E
0 ... 150 °C
E 0 7
0 ... 200 °C
E
0 ... 250 °C
E
0 ... 300 °C
E
0 ... 350 °C
E
0 ... 400 °C
E
0 ... 450 °C
E
3)
0 ... 500 °C
E
0 ... 600 °C
E
D 0 0
0 ... 700 °C
E
0 ... 800 °C
E
D 1 0
D 2 0
0 ... 900 °C
E
D 5 0
0 ... 1000 °C
E
7)
Y 2 0
0 ... 1200 °C
E
0 ... 1400 °C
E
0 ... 1600 °C
E
0 ... 1800 °C
E
50 ... 100 °C
E
50 ... 150 °C
E
100 ... 200 °C
E
100 ... 300 °C
E
100 ... 400 °C
E
200 ... 300 °C
E
200 ... 400 °C
E
200 ... 500 °C
E
300 ... 600 °C
E
500 ... 1000 °C
E
600 ... 1200 °C
E
800 ... 1600 °C
E
7)
Special range
Y
Measuring
3)
ranges
D 0 0 0 ... 100 Ω
E 4 0
D 1 0 0 ... 200 Ω
E 4 1
D 2 0 0 ... 500 Ω
E 4 2
D 5 0 0 ... 1000 Ω
E 4 3
Y 2 0 0 ... 2500 Ω
7)
E 4 4
0 ... 5000 Ω
8)
E 4 5
0 ... 6000 Ω
8)
E 4 6
7)
Special range
Y 3 1
E 5 0
-120 ... +1000 mV
10)
-1,2 ... +10 V
10)
-12 ... +100 V
10)
-120 ... +140 V
-12 ... +100 µA
10)
-120 ... +1000 µA
10)
10)
-1,2 ... +10 mA
10)
-12 ... +100 mA
10)
-120 ... +1000 mA
7)
Special range
Y 3 2
Siemens FI 01 · 2010
3/45
0
0
0
1
0
2
0
3
3
0
4
0
5
0
6
0
8
0
9
1
0
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
7
2
8
2
9
3
0
3
1
3
2
3
3
3
4
3
5
3
0