Siemens SITRANS TW Operator's Manual page 6

Transmitters for rail mounting

Advertisement

Ordering examples
Desired transmitter
Example 1:
SITRANS TW,
transmitter in four-wire system
• with explosion protection ATEX
• 230 V AC/DC power supply
• current output
• without sensor fault/limit monitor
- Sensor PT100, three-wire circuit
- Measuring range 0 ... 150 °C
- Temperature-linear characteristic
- Filter time 1 s
- Output 4 ... 20 mA, line filter 50 Hz
- Output driven to full-scale in event
of like breakage
Example 2:
SITRANS TW,
transmitter in four-wire system
• without explosion protection
• 24 V AC/DC power supply
• Voltage output
• Sensor fault/limit monitor
- Rating plate in English
- Sensor NiCr/Ni, type K
- Cold junction internal
- Measuring range 0 ... 950 °C
- Temperature-linear characteristic
- Filter time 1 s
- Output 0 ... 10 V, line filter 50 Hz
- Output driven to full-scale in event
of like breakage
- Limit monitoring switched off
Example 3:
SITRANS TW,
transmitter in four-wire system
• without explosion protection
• 24 V AC/DC power supply
• Current output
• without sensor fault/limit monitor
- Voltage input, measuring
range -1.2 V ... +10 V
- Measuring range 0 ... 5 V
- Source-proportional characteristic
- Filter time 10 s
- Output 0 ... 20 mA, line filter 60 Hz
- No monitoring for sensor fault
© Siemens AG 2009
SITRANS T measuring instruments for temperature
Parameter:
Ordering
design
Standard
Special
X
X
X
X
X
X
S76
A05
X
Y30
X
X
H10
X
X
A40
Y32
X
G07
H11
(X)
J03
Transmitters for rail mounting
four-wire system, universal, HART
Ordering information
The order number structure shown below is used to specify a
fully functioning transmitter. The selection of the operating data
(type of source, measuring range, characteristic etc.) is made
according to the following rules:
• Operating data already set in factory to default values:
The default settings can be obtained from the list of parame-
terizable operating data (see "Special operating data"). The
presets can be modified by the customer to match the require-
ments precisely.
• Operating data set on delivery according to customer require-
ments:
Supplement the Order No. by "-Z" and add the Order code
"Y01". The operating data to be set can be obtained from the
list of parameterize operating data. The Order codes A
K
for operating data to be set need only be specified in the
7 7
order if they deviate from the default setting.
The default setting is used if no Order code is specified for op-
erating data.
The selected parameters are printed on the transmitter's rating
plate.
SITRANS TW
to
7 7
Siemens FI 01 · 2010
3/43
3