Wiegand Interface Unit Two-State (WIU-2)

Installation Manual

Advertisement

Table of Contents
loading

Summary of Contents for GE WIU-2

  • Page 1: Installation Manual

    Wiegand Interface Unit Two-State (WIU-2) Installation Manual Security U.S. T 888 GE SECURITY (1 888 437 3287) F 561 998 6224 Asia T 852 2907 8108 F 852 2142 5063 Australia T 61 3 9259 4700 F 61 3 9259 4799...
  • Page 2 Trademarks GE and the GE monogram are registered trademarks of General Electric. and patents Wiegand Interface Unit-Two State (WIU-2) product and logo are trademarks of GE Security. Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products.
  • Page 3: Table Of Contents

    Testing the WIU-2 ..........15 Troubleshooting the WIU-2 ........16 Regulatory approvals .
  • Page 4 Wiegand Interfact Unit Two State (WIU-2) Installation Manual Figures Figure 1. Mounting instructions ..............7 Figure 2. WIU-2 connectors and jumpers..........9 Figure 3. Sample WIU-2 configuration ..........12 Figure 4. WIU-2 to M5 8RP Interface ............13 Figure 5. WIU-2 to M2000PX or M2000PXN Interface....14...
  • Page 5: Introduction

    When users present their credential (card, key fob, fingerprint, etc.) to the reader, the WIU-2 converts Wiegand badge identification (BID) data into the GE F/2F protocol and sends it to the controller. The GE access control system then grants or denies access to the secure location.
  • Page 6: Safety

    Wiegand Interface Unit Two State (WIU-2) Installation Manual Safety Radio interference WARNING: This is an FCC Class A product. In a domestic environment, this product may cause radio interference, in which case, the user may be required to take adequate measures.
  • Page 7: Product Features

    Product features Product features The WIU-2 is designed to provide the following functions: • Supports a wide range of Magnetic Stripe, Wiegand, Proximity, Mifare, and Biometric readers that employ Wiegand data formats • Converts both traditional and custom Wiegand BID formats to GE F/2F supervised protocol •...
  • Page 8: System Requirements

    Wiegand Interface Unit Two State (WIU-2) Installation Manual System requirements For UL compliant installation notes, refer to “UL Listed Installations” on page 16 Host software ® • Secure Perfect Edition 3.0 or later ™ • Picture Perfect 1.7 or later •...
  • Page 9: Technical Specifications

    UL 294 a. GE recommends using shielded cable for all installations. b. WIU-2 to Controller: The maximum cabling distance of 1,000 ft (304.8 meters) is influenced by wire gauge, reader power requirements, and the 12 VDC level from the controller.
  • Page 10: Parts List

    1. Mount the WIU-2. Refer to Mounting the WIU-2 on page 7. Note: The WIU-2 must be mounted indoors, in a protective enclosure or standard 1-gang electrical box (installer supplied) as shown in Figure 1. 2. Configure the WIU-2.
  • Page 11: Mounting The Wiu-2

    Mounting the WIU-2 Mounting the WIU-2 Figure 1. Mounting instructions 1. To mount the WIU-2 board in the single gang electrical box, first remove the electrical box cover and clean it with the alcohol wipes provided in the mounting hardware kit.
  • Page 12: Configuring The Wiu-2

    Wiegand Interface Unit Two State (WIU-2) Installation Manual Configuring the WIU-2 The following connectors and jumpers make up the Wiegand Interface Unit-2 • J1: Reader Interface Connector • J2: Controller Interface Connector • J3: 2-State Reporting Connector • J5: Reserved ™...
  • Page 13: Figure 2. Wiu-2 Connectors And Jumpers

    Configuring the WIU-2 Figure 2. WIU-2 connectors and jumpers...
  • Page 14: J1: Reader Interface Connector

    Wiegand Interface Unit Two State (WIU-2) Installation Manual J1: Reader interface connector The 10 pin connector J1 is the reader interface connector. J1 is used to connect a Wiegand output device to the WIU-2 Table 1. J1: Reader interface connector Description...
  • Page 15: J2: Controller Interface Connector

    Configuring the WIU-2 J2: Controller interface connector The 7-pin connector J2 is the controller interface connector. J2 is used to connect controller power and data signals to the WIU-2. Table 2. J2: Controller interface connector Description 12 VDC power for WIU-2...
  • Page 16: Connecting The Wiu-2

    Wiegand Interface Unit Two State (WIU-2) Installation Manual Connecting the WIU-2 Connect the WIU-2 between the GE controller and access control reader as indicated in Figure It is important to ensure all connections are made prior to applying power. Figure 3. Sample WIU-2 configuration...
  • Page 17: Wiring Diagrams

    Connecting the WIU-2 Wiring diagrams Figure 4. WIU-2 to M5 8RP Interface...
  • Page 18: Figure 5. Wiu-2 To M2000Px Or M2000Pxn Interface

    Wiegand Interface Unit Two State (WIU-2) Installation Manual Figure 5. WIU-2 to M2000PX or M2000PXN Interface...
  • Page 19: Testing The Wiu-2

    4. If an incorrect badge ID (BID) displays on the host, check for crossed lines between the WIU-2 and the reader. See Figure 4, “WIU-2 to M5 8RP Interface,” on page 13. or Figure 5, “WIU-2 to M2000PX or M2000PXN Interface,” on page 14., as appropriate.
  • Page 20: Troubleshooting The Wiu-2

    Always verify wiring against the wiring diagrams before powering up the system. Regulatory approvals UL Listed Installations The following are the results of the UL evaluation of the WIU-2 readers: • Operating temperature range: +32 F (+0 C) to +120 F (+49 C) •...
  • Page 21 Regulatory approvals GE Security MANUFACTURERS DECLARATION OF CONFORMITY Product identification: Model/type : WIU-2 BOM revision level Category (description) : Interface Board Brand : GE Security Manufacturer: GE Security B.V. GE Security GE Security Kelvinstraat 7 3211 Progress Dr. 791 Park of Commerce...