W8665A,E RF RECEIVER MODULE
W8665A
TV
L8124E,G,L
W8665A
T (TV)
L8124A,B,C,M
Fig. 5. Single zone hot water heat using an L8124A,B,C,M or L8148 Aquastat, an R8222 relay and a transformer.
69-1630-1
Y
W
G
T
Z
Fig. 4. Single zone hot water heat using an L8124E, G, L Aquastat.
Y
W
G
R8222
T
G
1
L1
2
L2
1
FACTORY INSTALLED JUMPER.
B1
BURNER
B2
C1
LINE VOLTAGE
CIRCULATOR
C2
G
1
2
1
FACTORY INSTALLED JUMPER.
B1
BURNER
B2
C1
LINE VOLTAGE
CIRCULATOR
C2
4
R C RZ
1
M20681
R C RZ
1
C
L2
R
L1
M20682A