Uniden UBC360CLT Owner's Manual

Uniden UBC360CLT Owner's Manual

Radio scanner

Advertisement

UBC360CLT
OWNER'S
MANUAL
OWNER'S MANUAL
UB355ZH(UBC360CLT).indd
1
2008/04/08
15:55:49

Advertisement

Table of Contents
loading

Summary of Contents for Uniden UBC360CLT

  • Page 1 UBC360CLT OWNER’S MANUAL OWNER'S MANUAL UB355ZH(UBC360CLT).indd 2008/04/08 15:55:49...
  • Page 2 Before you read anything else, please observe the following: Changes or modifications to this product not expressly approved by Uniden, or operation of this product in any way other than as detailed by this Reference Guide, could void your authority to operate this product.
  • Page 3 WARNING! Uniden does not represent this unit to be waterproof. To reduce the risk of fire or electrical shock, do not expose this unit to rain or moisture. Important: If you use the supplied AC adapter to power the scanner but have not installed batteries in the scanner, never turn the scanner off by disconnecting the AC adapter or unplugging it from the AC outlet.
  • Page 4: Table Of Contents

    Birdies ..........7 Contents UB355ZH(UBC360CLT).indd 2008/04/08...
  • Page 5 Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Contents UB355ZH(UBC360CLT).indd 2008/04/08...
  • Page 6: Unpacking Your Scanner

    Unpacking Your Scanner Please unpack this box carefully and make sure you have: Telescopic Antenna Scanner Radio This Owner’s Manual Other Printed Material AM Loop Antenna AC Adapter 3 AA Alkaline Batteries Unpacking Your Scanner UB355ZH(UBC360CLT).indd 2008/04/08 15:55:52...
  • Page 7: Introduction

    1.5 137.0000 - 137.9950 138.0000 - 157.9875 1.5 158.0000 - 160.5900 160.6000 - 16.5875 1.5 16.6000 - 173.9900 06.0000 - 39.9937 6.5 0.0000 - 65.9950 66.0000 - 69.9900 70.0000 - 51.0000 6.5 806.0000 - 960.0000 1.5 Introduction UB355ZH(UBC360CLT).indd 2008/04/08 15:55:52...
  • Page 8: Features

    50 channels per second maximum in SCAN MODE. • Search Speed 50 steps per second maximum in SEARCH MODE. • TURBO MODE For frequency steps 5kHz apart, searching occurs in Turbo Mode which is 150 steps per second. Introduction UB355ZH(UBC360CLT).indd 2008/04/08 15:55:52...
  • Page 9 The backup provides backup for the clock when power is off and will power scanning for a short time. Auto Power Off — turns the scanner off when the battery power gets too low. Introduction UB355ZH(UBC360CLT).indd 2008/04/08 15:55:52...
  • Page 10: Controls

    Controls Scanner Introduction UB355ZH(UBC360CLT).indd 2008/04/08 15:55:54...
  • Page 11 11 ./CLR — this key has three functions: • press to input a decimal point when you enter a frequency. • press to cancel a numeric key input − 0 to 9. • press to clear an error display. Introduction UB355ZH(UBC360CLT).indd 2008/04/08 15:55:54...
  • Page 12 20 HEADPHONE Jack — lets you use an headphone for private listening. 21 Antenna Connector — connect an external antenna using a BNC connector. AM RADIO ANT connector — connect the supplied loop antenna and position it for best AM Broadcast radio reception. Introduction UB355ZH(UBC360CLT).indd 2008/04/08 15:55:54...
  • Page 13 The backlight turns off automatically after 15 seconds from the last key stroke (if not permanently turned on). The scanner sounds special tones as follows: • to confirm key entry. • to indicate an error in key entry, • to indicate low battery voltage. Introduction UB355ZH(UBC360CLT).indd 2008/04/08 15:55:57...
  • Page 14: Setting Up The Scanner

    • Always remove old or weak batteries. Batteries can leak chemicals that destroy electronic circuits. • Do not mix old and new batteries, different types of batteries (standard, alkaline, or rechargeable) or rechargeable batteries of different capacities. Setting Up The Scanner UB355ZH(UBC360CLT).indd 2008/04/08 15:55:59...
  • Page 15: Connecting An Antenna

    To turn on the backlight for 15 seconds, tap SNOOzE/Backlight. To turn on the backlight permanently, press and hold SNOOzE/Backlight for over  seconds. To turn off the backlight, press and hold SNOOzE/Backlight again. Setting Up The Scanner UB355ZH(UBC360CLT).indd 2008/04/08 15:56:00...
  • Page 16: Using The Alarm Clock

    3. Press ▲ or ▼ to change the minute setting by one minute or press the appropriate number keys to enter the minutes. Press E/PGM to set the minutes. . To lock in the alarm time, move the slide switch to Clock. Using the Alarm Clock UB355ZH(UBC360CLT).indd 2008/04/08 15:56:01...
  • Page 17: Using Snooze

    0 minutes, then reset to alert you again the following day. Using Snooze When the alarm sounds, press the snooze bar to silence the alarm for 5 minutes. Using the Alarm Clock UB355ZH(UBC360CLT).indd 2008/04/08 15:56:02...
  • Page 18: Listening To Am/Fm Channels

    To quickly recall a channel, select the band, select the channel memory mode by pressing PRI/MEM, then tap the number button that corresponds to the memory where the channel is stored. Listening to AM/FM Channels UB355ZH(UBC360CLT).indd 2008/04/08 15:56:03...
  • Page 19: Using The Scanner Memories

    (The numbers in the left-hand columns below correspond to your scanner’s memory numbers.) Bank 1 Bank 2 Bank 3 Bank 4 Bank 5 Using the Scanner Memories UB355ZH(UBC360CLT).indd 2008/04/08 15:56:04...
  • Page 20 . To program the next memory, press ▲ or ▼ and repeat step 3. To program a different memory, repeat from step . 5. To exit program mode, press HOLD or SCAN or change the scanner’s mode. Using the Scanner Memories UB355ZH(UBC360CLT).indd 2008/04/08 15:56:04...
  • Page 21: Selecting A Memory

    To unlock all memories of the bank, press and hold L/O for  seconds, the scanner beeps twice and the icon disappears. Using the Scanner Memories UB355ZH(UBC360CLT).indd 2008/04/08 15:56:04...
  • Page 22: Using Priority Scan

    Delay is turned on by default when you program a memory. To turn Delay off (or back on), first, select the channel. Then, press DELAY. The scanner turns on the icon for memories that have been DELAY programmed with delay. Using the Scanner Memories UB355ZH(UBC360CLT).indd 2008/04/08 15:56:05...
  • Page 23: Searching For Active Frequencies

    Searching stops at a frequency when transmission is found. Searching resumes automatically after the transmission ends. Press SEARCH or ▲, ▼ to start aircraft search when search stops at a frequency. Search direction can be changed by ▲, ▼. Searching for Active Frequencies UB355ZH(UBC360CLT).indd 2008/04/08 15:56:05...
  • Page 24: Saving A Found Frequency Into A Scan Memory

    Then manually step to the frequency using the ▲/▼ keys. When you have selected the frequency, press L/O. Notes: • Up to 50 frequencies can be skipped for limit search. • Up to 50 frequencies can be skipped for Aircraft Band search. Searching for Active Frequencies UB355ZH(UBC360CLT).indd 2008/04/08 15:56:05...
  • Page 25: Select Step Operation

    By pressing STEP in scan (hold) mode, limit search (hold) mode and aircraft search (hold) mode, go to select step menu. STEP 2: Press BAND, and then press ▲, ▼ key to change the band. Holding ▲ or ▼ change the band continuously. Select Step Operation UB355ZH(UBC360CLT).indd 2008/04/08 15:56:06...
  • Page 26 • The all lockout frequencies of the band automatically can be unlocked when the step is changed at the Band. • The frequency can be programmed by 5kHz step even though the step is set up to 15kHz or 0kHz. Select Step Operation UB355ZH(UBC360CLT).indd 2008/04/08 15:56:06...
  • Page 27: Care And Maintenance

    All radios can receive “birdies” (undesired signals). If your scanner stops during Scan mode and no sound is heard, it might be receiving a birdie. Birdies are internally generated signals inherent in the electronics of the scanner. Press L/O to lock out the channel. Care and Maintenance UB355ZH(UBC360CLT).indd 2008/04/08 15:56:06...
  • Page 28: Technical Specifications

    5 / 6.5 / 8.33 / 10 / 1.5 / 15 / 0 / 5 / 50 / 100 kHz or AUTO *(for 800 MHz Band 1.5 / 15 / 0 / 5 / 50 / 100 kHz or AUTO) Radio Mode 0.500 to 1.700 10 kHz 87.3000 to 107.9000 100 kHz Technical Specifications UB355ZH(UBC360CLT).indd 2008/04/08 15:56:06...
  • Page 29 Storage Temp C to +60 − × × Size : 09(W) 17.75(D) 80.7(H) mm Weight : 600g (without batteries and antenna) Features, specification, and availability of optional accessories are all subject to change without notice. Technical Specifications UB355ZH(UBC360CLT).indd 2008/04/08 15:56:06...
  • Page 30: Declaration Of Conformity

    We: Uniden Corporation -1-7 Hatchobori Chuo-Ku, Tokyo 10-851 Japan declare, under our sole responsibility, that this equipment: Uniden Bearcat model UBC360CLT is in compliance with the essential requirements and other relevant provisions of the Council Directive 1999/5/EC. Declaration of Conformity UB355ZH(UBC360CLT).indd...
  • Page 31 Memo UB355ZH(UBC360CLT).indd 2008/04/08 15:56:07...
  • Page 32 THANK YOU FOR BUYING A UNIDEN PRODUCT. ©2008 Uniden Corporation Printed in China UBZZ01355ZZ(0) UB355ZH(UBC360CLT).indd 2008/04/08 15:56:13...

Table of Contents