Kenwood DPX701 Service Manual page 9

Hide thumbs Also See for DPX701:
Table of Contents

Advertisement

MICROCOMPUTER'S TERMINAL DESCRIPTION
Pin No.
Pin Name
Module
µCOM
85
VCC2
86
EXT_AMP_CON EXTRA
µCOM
87
VSS
88~91
TYPE_1~4
TYPE
92
NC
93
OEM_DISP_DATA EXTRA
93
NC
94
OEM_DISP_CLK EXTRA
94
NC
95
OEM_DISP_CE
EXTRA
95
NC
96
NC
97
P_CON
Power supply O
98
NC
99
ANT_CONT
EXTRA
100
ILLUMI_DET
EXTRA
101
BU_DET
EXTRA
102
ACC_DET
EXTRA
103
(PWIC_SVR)
PWIC
104
PWIC_MUTE
PWIC
105
PWIC_STBY
PWIC
106
LX_CON
LX_M
107
MUTE_PRE_R
AUDIO
108
MUTE_PRE_L
AUDIO
109
MUTE_0
AUDIO
110
MUTE_1
AUDIO
111
MUTE_2
AUDIO
112
MUTE_A
AUDIO
113
MUTE_PRE_SW AUDIO
114
MUTE_AFS
AUDIO
I/O
Application
-
I/O EXTERNAL AMP control
-
I
Destination switching
O
Not used
I/O External display DATA
O
Not used with DISP OUT
I/O External display CLK
O
Not used with DISP OUT
I/O External display control request
O
Not used with DISP OUT
O
Not used
External amplifier control terminal
O
Not used
O
Power antenna control
I
Dimmer illumi detection
I
Momentary power down detection
I
ACC power supply detection
O
SVR discharging circuit
O
Power ICMUTE terminal
O
Power IC standby control
O
Start-up request to slave unit
O
PRE_OUT MUTE Rch
O
PRE_OUT MUTE Lch
O
E-VOL FRONT MUTE terminal
O
E-VOL REAR MUTE terminal
O
E-VOL SW MUTE terminal
O
E-VOL SPEANA MUTE terminal
O
PRE_OUT MUTE SUB
O
AFS MUTE terminal
DPX701/701U/701UY
DPX-MP7090U
Truth
Processing Operation Description
value table
y
Refer to the truth value table
Output L fixed
External display
Output L fixed
External display
Output L fixed
External display
Output L fixed
Output L fixed
POWER ON: H, POWER OFF: L,
ALL OFF: L
Output L fixed
TUNER ON: H
L: ON, H: OFF
L: BU found,
H: BU not found, momentary power down
L: ACC ON, H: ACC OFF
H: For 5 seconds at POWER OFF
momentary power down, L: Thereafter
L: While STANDBY source, momentary
power down, L: While TEL MUTE
POWER ON: H, POWER OFF: L
H: Slave unit ON, L: Slave unit OFF
L: When M MUTE R is L (while CD)
L: At momentary power down, Fixed to
H: Only when 2 zone or NAVI interruption
L: When M MUTE L is L (while CD)
L: At momentary power down, Fixed to
H: Only when 2 zone or NAVI interruption
ON: L, OFF: H
ON: L, OFF: H
ON: L, OFF: H
ON: L, OFF: H
L: ON, H: OFF
L: At momentary power down
Use in conjunction when using MUTE2
(anti- MUTE2 shock noise measure)
IC2's MUTE C is used
L: ON, H: OFF, Decay time constant 0.5ms
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dpx701uDpx701uyDpx-mp7090u

Table of Contents