ULTRA-MAX™ GAS HOTPLATE MODELS
HOTPLATE DE GAZ ULTRA-MAX™ MODELES
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause
property damage, injury or death.
the installation, operating and maintenance
instructions thoroughly before installing or
servicing this equipment.
AVERTISSEMENT: L'installation inexacte, le
réglage, le changement, le service ou l'entretien
peuvent causer des dégats matériels, des dommages
ou la mort. Lisez les instructions d'installation,
d'opération et d'entretien complètement avant
d'installer ou entretenir ce matériel.
FOR YOUR SAFETY:
gasoline or other fl ammable vapors or liquids
in the vicinity of this or any other appliance.
POUR VOTRE SÛRETÉ: N'enregistrez pas ou
n'utilisez pas l'essence ou d'autres vapeurs ou
liquides infl ammables à proximité de ceci ou d'aucun
autre appareil.
Star
Manufacturing
International Inc.
10 Sunnen Drive
St. Louis, MO 63143
Phone: (314) 781-2777
Fax: (314) 781-2714
802H, 804H,
806H, and 808H
Read
Do not store or use
WARNING:
This appliance shall be installed
in accordance with current regulations and
used only in well-ventilated space. Refer to
instructions before installing and using this
appliance.
AVERTISSEMENT: Cet appareil sera installé
selon des règlements actuels et utilisé
seulement dans l'espace bien-aéré. Référez-
vous aux instructions avant d'installer et utiliser
cet appareil.
In addition, there should be posted, in a
prominent location, detailed instructions to
be followed in the event the operator smells
gas. Obtain the instructions from the local gas
supplier.
En outre, là devrait être signalé, dans un
emplacement en avant, des instructions détaillées
d'être suivi en cas que l'opérateur sent le gaz.
Obtenez les instructions du fournisseur local de
gaz.
Installation and
Operating Instructions
Instructions d'installation
et d'opération
2M-Z5486 Rev. A
7/30/06

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 802H and is the answer not in the manual?

Questions and answers

Summary of Contents for Star 802H

  • Page 1 Phone: (314) 781-2777 Fax: (314) 781-2714 2M-Z5486 Rev. A 7/30/06 ULTRA-MAX™ GAS HOTPLATE MODELS HOTPLATE DE GAZ ULTRA-MAX™ MODELES 802H, 804H, 806H, and 808H WARNING: Improper installation, adjustment, WARNING: This appliance shall be installed alteration, service or maintenance can cause in accordance with current regulations and property damage, injury or death.
  • Page 2: Safety Symbol

    RETAIN THIS MANUAL FOR FUTURE REFERENCE NOTICE Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability. Star reserves the right to change specifi cations and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
  • Page 3: Specifications

    SPECIFICATIONS 802H Type: Manual Control, 2-Burner 2 Controls, 60,000 BTUH Total Natural Gas (30,000 BTUH Nat/26,000 BTUH LP per burner) Approximate Weight: Installed - 70 Lb s (31.7 kg), shipping - 120 Lbs (54.4 kg) Dimensions: 12" - Width, 30 5/8" - Depth, 14 7/8" - Height (30.5 cm - Width, 77.8 cm - Depth, 37.8 cm - Height)
  • Page 4: General Installation Data

    GENERAL INSTALLATION DATA CAUTION This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations. The Ultra-Max™...
  • Page 5: Leveling Unit

    LEVELING UNIT This hotplate is supplied with 4 feet or fl oor stand legs which must be screwed into the body. Unit must CAUTION be level. Level unit by adjusting the (4) feet which DO NOT INSTALL WITHOUT ATTACHING have an adjustment of 1-3/4" for accurate and perfect line-up with other units.
  • Page 6 GAS PIPING Gas piping shall be of such size and so installed as to provide a supply of gas suffi cient to meet the full gas input of the appliance. If the appliance is to be connected to existing piping, it shall be checked to determine if it has adequate capacity.
  • Page 7: Operating Instructions

    PILOT LIGHTING INSTRUCTIONS The hotplate is equipped with factory pre-set standing pilots and should be lit immediately after the gas is turned on. Pilot lights may need an adjustment based on local gas supplies. See below for pilot light adjustments. If the operator smells gas or the pilot lights need to be relit: 1.
  • Page 8: Entretien Et Réparations

    L’utilisation de toute pièce autre que les pièces d’origine STAR dégage le fab- ricant de toute responsabilité. Star se réserve le droit de changer les spécifi cations et la conception du produit sans préavis. Ces changements ne donnent pas le droit à l’acheteur d’obtenir les changements, améliorations, ajouts ou remplacements correspondants pour...
  • Page 9 DONNÉES GÉNÉRALES D’INSTALLATION ATTENTION Cet équipement n’est conçu et vendu que pour l’utilisation commerciale par le personnel formé et sachant l’utiliser et il n’est pas vendu pour l’utilisation à la maison, ni pour l’usage du public dans les endroits de pique-nique. Le hotplate de la série Ultra-Max est équipé...
  • Page 10 ÉQUILIBRAGE DE L’APPAREIL Ce hotplate est assuré avec 4 pieds ou jambes de stand de plancher qui doivent être vissés dans le ATTENTION corps. L'unité doit être niveau. Équilibrer l’appareil en ajustant les (4) pieds qui ont un réglage de 1-3/4 N’INSTALLEZ PAS SANS ATTACHER ES po., en vue d’un alignement exact et parfait avec PIEDS OU DES JAMBES ET L'ETAGERE...
  • Page 11 TUYAUTERIE À GAZ La taille de la tuyauterie à gaz et la façon dont elle est installée doivent être telles qu’elle fournisse une alimentation suffi sante de gaz pour répondre aux exigences d’admission de pleine puissance dans l’appareil. S’il faut raccorder l’appareil à la tuyauterie existante, il faut vérifi er cette dernière pour déterminer si elle a la capacité...
  • Page 12 INSTRUCTIONS CONCERNANT LES VEILLEUSES D’ALLUMAGE Le hotplate est équipé des pilotes debout préréglés par usine et devrait être allumé juste après que le gaz est allumé. Les lampes témoin peuvent avoir besoin d’un réglage basé sur les approvisionnements de gaz locaux.
  • Page 13 NETTOYAGE Nettoyez régulièrement. Soyez sûr que l’appareil a refroidi. Enlevez la section de grille et la tête de brûleur pour descendre pour le lavage. La brosse dehors carboned des particules. Le venturi doit être exempt de la graisse, de la saleté, de la fi bre, ou de n’importe quel matériel étranger.
  • Page 14 LIMITED EQUIPMENT WARRANTY All workmanship and material in Star products have a one (1) year limited warranty on parts & labor in the United States and Canada. Such warranty is limited to the original purchaser only and shall be effective from the date the equipment is placed in service. Star's obligation under this warranty is limited to the repair of defects without charge, by the factory authorized service agency or one of its sub-agencies.
  • Page 16: Parts List

    PARTS LIST July 30, 2006, Rev. A 802H, 804H, 806H and 808H Ultra-Max Gas Hotplates MODEL Number Part Number Description Number Unit 2F-Z0637 (All) 2/4/6/8 Grate 2F-Z5473 (All) 2/4/6/8 Burner Set I5-Z5463 (All) 2/4/6/8 Pilot Bracket I5-Z5464 (All) 1/2/3/4 Burner Bracket...