Optiview Mini Speed Dome Camera Instruction Manual

10x mini speed dome camera

Advertisement

Quick Links

MINI SPEED DOME CAMERA
10X Mini Speed Dome Camera
Instruction Manual
Rev 1.01 dated on Dec.04, 2006

Advertisement

Table of Contents
loading

Summary of Contents for Optiview Mini Speed Dome Camera

  • Page 1 MINI SPEED DOME CAMERA 10X Mini Speed Dome Camera Instruction Manual Rev 1.01 dated on Dec.04, 2006...
  • Page 2: Table Of Contents

    Warning & Caution What’s in the Box? General Features Names of Each Part Installation A. Connection Methods B. Ceiling Mount Type C. Embedded Mount Type Quick Operating Keys Diagnostic OSD Menu Setting A. OSD Menu Table B. DOME SET C. CAMERA SET D.
  • Page 3: Warning & Caution

    WARNING & CAUTION If you fail to read this information and handle the product incorrectly, death or serious injury may occur. The unit should be installed by the trained Personnel. Always stop using when the product emits smoke or abnormal heat. Never install the product in area exposed to water, oil or gas.
  • Page 4: General Features

    GENERAL FEATURES 100X Zoom Mini Speed Dome 10X Optical Zoom with 10X digital zoom ±0.02° dome system accuracy with 1/4 micro step With 0.1° technical accuracy, camera provides excellent sensitive and delicate controlling on preset mode by adapting 1/4 micro step and twin gear system 360°...
  • Page 5: Names Of Each Part

    NAMES OF EACH PAR T 1. Surface Mount Adaptor 2. Cap Screw ( PT3/4 , 2EA ) 3. Dip Switch 4. Terminal Block 5. Main body...
  • Page 6: Installation

    INSTALLATION A. CONNECTION MATHOD Loose the screws on the domes cover and remove it from the base. (Screws won’t be removed) Loose the screws which connect mount cover and Main base and separate dome cover from the main base. (Screws won’t be removed) Connect power (DC12V 1.5 A) to Power and GND.
  • Page 7: Ceiling Mount Type

    INSTALLATION B. CEILING MOUNT TYPE 1. Fix the surface mount adaptor with 4pcs of screws on the place where you want to install. (FIG.4) 2. When you use pipe, please note the standard size of pipe. (FIG.5) 3. You can re-assemble the domes.
  • Page 8: Quick Operating Keys

    QUICK OPERATING KEYS This dome provides three protocols mainly as Pelco D, Pelco P. These protocols are able to use with other DVR or Controller if the equipment has the above protocols. Default setting of this dome is Pelco D / P (auto detection) with 2400 bps (baud rate). As the merit of this product, it has lots of function keys to support the following functions.
  • Page 9: Diagnostic

    QUICK OPERATING KEYS DIAGNOSTIC When Power on, DIAGONOSTIC is operated. The following messages are displayed on the monitor. CAMERA ID : 001 BAUD RATE : 2400 BPS WAITING……… PAN ORIGIN TILT ORIGIN TX CONNECTION CAMERA COMM Pan Origin Test Zero point of Pan is founded after Panning test. Tilt Origin Test Zero point of Tilt is founded after Tilting test.
  • Page 10: Osd Menu Setting

    OSD MENU SETTING A. OSD MENU TABLE...
  • Page 11: Dome Set

    OSD MENU SETTING To enter OSD Menu, press the button 95 + PRESET. MAIN MENU DOME SETUP CAMERA SET AUTO SCAN TOUR PRAVACY PATTERN ALARM SECTOR EXIT * Use the joystick “up down” to move the position and “left right” to make selection B.
  • Page 12 OS D MENU S ETTING B-2. DOME SET - RECOVER This feature allows the dome to work from the last setting before you use the dome manually (Auto scan, group tour, preset, pattern or sectors), after the set time, even power shut down and it turns on again.
  • Page 13 OSD MENU SETTING DOME SET – [NEXT PAGE] – [PASSWORD] B-8-2. To enter this page to set a password, move joystick to the right direction. The password must be set by preset number from 001 to 255 (Default 99) A. OSD MAIN MENU TABLE (PAGE 14) default setting is BLANK. ENTER PASSWORD BY ENTERING PRESET CODE PASSWORD ***...
  • Page 14 OSD MENU SETTING OSD DISPLAY CAMERA ID : OFF PRESET ID : OFF SECTOR ID : OFF COORDINATE : ON [PREVIOUS PAGE] DOME SET – [NEXT PAGE] – [SYSTEM STATUS] B-8-4. This page shows the information of this camera. SYSTEM STATUS PROTOCOL : PELCO D, P BAUD RATE...
  • Page 15 OSD MENU SETTING - To clear memorize any data, move joystick to the right direction when cursor is on each item. TOUR CLEAR ARE YOU SURE? YES NO Press FOCUS NEAR button when the cursor is at YES in order to clear memorized data. Then flickered each item such as tour, preset, sector and so on is displayed on the monitor about 2~3 seconds.
  • Page 16: Camera Set

    OSD MENU SETTING C. CAMERA SET CAMERA SET FLICKER : OFF MIRROR : OFF APERTURE : 10 D ZOOM : OFF WB MODE : AWB MODE PIC FLIP : OFF : OFF D/N MODE : AUTO DSS MODE : OFF EXIT <10X >...
  • Page 17 OSD MENU SETTING CAMERA SET – PIC FLIP C-6. Picture flip feature provides the top and down exchanged picture image horizontally. Move joystick to the right or left direction to select OFF/ON. The default setting is OFF. C-7. CAMERA SET – BLC (Back Light Compensation) The default setting is OFF and BLC modes can be OFF/ON.
  • Page 18: Preset

    OSD MENU SETTING D. PRESET SET To enter PRESET SET, move joystick to the right direction. PRESET SET PRESET NO :001 PRESET ID :PRESET001------- PAN :XXX.XX TILT : XXX.XX SAVE EXIT PRESET – PRESET NO. D-1. Up to 165 numbers of preset positions are available. Move joystick to the right or left direction to select preset no.
  • Page 19: Auto Scan

    OSD MENU SETTING E. AUTO SCAN SET * 66 + preset button is working as AUTO SCAN after setting. AUTO SCAN SET START ANGLE : XXX.X.XX.X END ANGLE : XXX.X.XX.X DIRECTION : CW ENDLES : OFF SPEED : 10°/S DWELL TIME : 03 SAVE AND EXIT EXIT...
  • Page 20: Tour Set

    OSD MENU SETTING F. TOUR SET 8 Programmable tours can be set and each tour is available to set up to 64 preset steps. After setting the data to the each tour group, 71~78 + preset buttons are working as group tour # 1~8 TOUR SET TOUR NO : 01...
  • Page 21: Privacy Set

    OSD MENU SETTING G. PRIVACY SET 4 Privacy masking zones are available to block out areas of security. PRIVACY SET PRIVACY NO DISPLAY ACTION SAVE EXIT PRIVACY SET – PRIVACY NO. G-1. It provides up to 4 privacy masking zones PRIVACY SET –...
  • Page 22: I. Alarm Set

    8 programmable patterns are available with 16 characters of title. After setting the data to each pattern # 1~8, 81~88+ preset buttons are working as Pattern # 1~8. PATTERN SET PATT NO : 01 PATT TITLE: PATTERN01□□□□□□□ DATA FILL : 0% SAVE EXIT PATTERN SET –PATT NO.
  • Page 23 4 Alarm inputs are available and each alarm is activating to presets, group tours or patterns. ALARM SET ALARM NO : 01 ALARM INPUT: OFF ALARM ACT : 001 SAVE EXIT I-1. ALARM SET – ALARM NO. Up to 4 alarms are selectable by using joystick to the right direction when cursor is on ALARM NO. ALARM SET –...
  • Page 24: Sector Set

    OSD MENU SETTING J. SECTOR SET Up to 8 programmable sectors are available with 16 characters. This feature is useful to memory the certain location such as parking zone or so on. When camera goes through this area, it shows the letter you memorized. SECTOR SET SECTOR NO : 01...
  • Page 25: Dip Switch Setting

    DIP SWITCH SETTING A-1. DIP SW SETTING Mini Speed Dome camera provides up to 63 cameras ID and it’s an adjustable ID with 1 switch. Open the camera case to set ID using DIP SW1. * Factory default: Camera ID = 1, PELCO-D Baud Rate: 2400bps A-2.
  • Page 26: Protocol/ Baud Rate Setting (Dip Sw1-9~10)

    DIP SWITCH SETTING A-3. PROTOCOL dip switches are used for Protocol Setting. Factory Default: Pelco-D or Pelco-P (Auto detection) DIP SW1- 7 A-4. BAUD RATE SETTING The 9 Dip Switch is used for BAUD RATE setting. DIP SW can be changeable to 2400bps, 9600bps. Factory Default: 2400bps.
  • Page 27: Troubleshooting

    TROUBLESHOOTING If you have trouble in operating in your camera, refer to the following. PROBLEM No operating No picture Dark screen Abnormal camera Operation status Screen not clear SOLUTION Check if the power supply is DC12V. Check if RS-485 communication cable is connected correctly. Check camera ID setting.
  • Page 28: Specification

    SPECIFICATIONS MODEL Pan Rotation Angle Manual Pan Speed Preset PAN /TILT Tilt Rotation Angle Manual Tilt Speed Preset System Accuracy Presets Group Tour Auto scan Pattern Privacy Zone FUNCTIONS Sector Password Protection Alarm Input Alarm Actions Auto Flip OSD Menu Communication Protocol Consumption (12V DC)
  • Page 29: Dimension

    DIMENSIONS...
  • Page 30: General Information

    You will need to have this ready prior to calling our Optiview Technical support group to avoid delay or denial of support for this product. You may also use your Order number or Invoice number as your reference prior to calling us for technical...
  • Page 31: Return Policy

    Cable must be unopened (or still on reel). A Return Merchandise Authorization (RMA) number must be obtained from Optiview prior to the return of any merchandise. An RMA number is only valid for 14 days (returned products must be received within 14 days from issuance of the RMA number).

Table of Contents