Service Mode; Cat (Computer Aided Test) Mode - Panasonic TH-50LFE7U Servise Manual

Hide thumbs Also See for TH-50LFE7U:
Table of Contents

Advertisement

5 Service Mode

5.1.

CAT (Computer Aided Test) mode

How to access the CAT mode.
Method A Main unit + remote control operation
Press and hold the
button on the rear side of the unit and press the RECALL button on the remote control 3 times quickly
within 2 second, this will place the unit into the CAT mode.
Method B Remote control operation only
1. Set the OFF timer except for [0] minute by OFF TIMER button. (30 minutes, 60minutes, 90 minutes)
2. Set the volume level of sound to 0 by VOL down button / -button.
3. Press the RECALL button more than 3 seconds before a volume display disappears.
To exit the CAT mode, turn the power off by the main unit or a remote control.
5.1.1.
IIC mode
Select the IIC mode by Up/Down button on the remote control at the front page of CAT mode and then press the Action button on
the remote control.
Subject and item are mentioned on "IIC mode structure".
To exit the IIC mode, press the R button on the remote control.
TH-50LFE7U/TH-50LFE7W/TH-50LFE7E
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Th-50lfe7eTh-50lfe7w

Table of Contents