5.2. Enroll in the ZigBee Security System......................4 5-3. Alert Test.................................5 5-4. Air Pollution Sensing............................5 5-5. Announce and Restart............................. 5 5-6. Low Voltage alert and Temperature Sensor....................5 5-7. Restore to Factory Setting..........................6 6. Home Automation Clusters for ZA02A......................... 7 7. Important Maintenance Instructions........................9...
(Zone device) in the ZigBee security system. It can detect NH3, NO2, Ethanol (EtOH), SO2, and smoke. When the air quality goes below a specified level, ZA02A would generate the sound to alert users.
5-1. Join the ZigBee Network After ZA02A is turned on, it will search for an existing ZigBee network with the same channel and send a request to join the network automatically. While ZA02A is under the coverage from a coordinator or a router whose permit-join feature is enabled, ZA02A will be permitted to join the network.
The indicator keeps flashing. 4. If ZA02A is in the network but not enrolled → the buzzer rings for 5 seconds (3-5 times) and dual color indicator flashes alternately for 5 times. In the mean time, it sends the enrollment request. After the enrollment is successful, it will generate an alert sound when it is enrolled successfully.
Over 60 degrees, it will send high temperature alert to CIE devices. In the mean time, the buzzer and dual color indicator flashes alternately. 5-7. Restore to Factory Setting If users would like to join device into a new network, it needs to be restored. To restore it to factory setting, please follow the steps: Step1.
A cluster is a set of related attributes and commands which are grouped together to provide a specific function. A simple example of a cluster would be the On/Off cluster which defines how an on/off switch behaves. This table lists the clusters which are supported by ZA02A. 1.End Point(s):0x01 2.Device ID:HA IAS ZONE(0x0402)...
Page 9
Mandatory Identifier Name Type Range Access Default / Optional 0x0007 PowerSource 8-bit 0x00 – 0xff Read only 0x03 Enumeration 0x0010 LocationDescription Character string 0 – 17 bytes Read/write 0x0011 PhysicalEnvironment 8-bit 0x00 –0xff Read/write 0x00 Enumeration 0x0012 DeviceEnabled Boolean 0x00 –0 0x01 Read/write 0x01...
7. Important Maintenance Instructions Please keep the device in a dry place. Precipitation, humidity, and all types of liquids or moisture can contain minerals that corrode electronic circuits. In cases of accidental liquid spills to a device, please leave the device dry properly before storing or using.