netvox ZA02A Manual

Wireless smoke detector (photoelectric)

Advertisement

Quick Links

ZA02A
Wireless Smoke Detector (Photoelectric)
ZA02A
Wireless Smoke Detector
(Photoelectric)
Firmware: V3.1
Hardware: V4.1
20150430

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZA02A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for netvox ZA02A

  • Page 1 ZA02A Wireless Smoke Detector (Photoelectric) ZA02A Wireless Smoke Detector (Photoelectric) Firmware: V3.1 Hardware: V4.1 20150430...
  • Page 2: Table Of Contents

    5.2. Enroll in the ZigBee Security System......................4 5-3. Alert Test.................................5 5-4. Air Pollution Sensing............................5 5-5. Announce and Restart............................. 5 5-6. Low Voltage alert and Temperature Sensor....................5 5-7. Restore to Factory Setting..........................6 6. Home Automation Clusters for ZA02A......................... 7 7. Important Maintenance Instructions........................9...
  • Page 3: Introduction

    (Zone device) in the ZigBee security system. It can detect NH3, NO2, Ethanol (EtOH), SO2, and smoke. When the air quality goes below a specified level, ZA02A would generate the sound to alert users.
  • Page 4: Product Appearance

    2. Product Appearance Binding Key Test Key Indicator Sensor Mounting...
  • Page 5: Specification

    5-1. Join the ZigBee Network After ZA02A is turned on, it will search for an existing ZigBee network with the same channel and send a request to join the network automatically. While ZA02A is under the coverage from a coordinator or a router whose permit-join feature is enabled, ZA02A will be permitted to join the network.
  • Page 6: Alert Test

    The indicator keeps flashing. 4. If ZA02A is in the network but not enrolled → the buzzer rings for 5 seconds (3-5 times) and dual color indicator flashes alternately for 5 times. In the mean time, it sends the enrollment request. After the enrollment is successful, it will generate an alert sound when it is enrolled successfully.
  • Page 7: Restore To Factory Setting

    Over 60 degrees, it will send high temperature alert to CIE devices. In the mean time, the buzzer and dual color indicator flashes alternately. 5-7. Restore to Factory Setting If users would like to join device into a new network, it needs to be restored. To restore it to factory setting, please follow the steps: Step1.
  • Page 8: Home Automation Clusters For Za02A

    A cluster is a set of related attributes and commands which are grouped together to provide a specific function. A simple example of a cluster would be the On/Off cluster which defines how an on/off switch behaves. This table lists the clusters which are supported by ZA02A. 1.End Point(s):0x01 2.Device ID:HA IAS ZONE(0x0402)...
  • Page 9 Mandatory Identifier Name Type Range Access Default / Optional 0x0007 PowerSource 8-bit 0x00 – 0xff Read only 0x03 Enumeration 0x0010 LocationDescription Character string 0 – 17 bytes Read/write 0x0011 PhysicalEnvironment 8-bit 0x00 –0xff Read/write 0x00 Enumeration 0x0012 DeviceEnabled Boolean 0x00 –0 0x01 Read/write 0x01...
  • Page 10: Important Maintenance Instructions

    7. Important Maintenance Instructions  Please keep the device in a dry place. Precipitation, humidity, and all types of liquids or moisture can contain minerals that corrode electronic circuits. In cases of accidental liquid spills to a device, please leave the device dry properly before storing or using.