Troubleshooting and Testing
Procedure
Component Test
Letter
10. Disconnect the power supply cord, and then remove outer case.
P
11. Open the door and block it open.
12. Discharge high voltage capacitor. (See Warnings and Instructions on page 3-1)
13. Disconnect the dummy resistor circuit from the sensor connector of control panel.
14. Carry out necessary repair.
15. Reconnect all leads removed from components during testing and repairing.
16. Re-install the outer case (cabinet).
17. Reconnect the power supply cord after the outer case is installed. Run the oven and check all
functions.
18. Carry out "Water load cooking test" again and ensure that the oven works properly.
Sensor Dummy Resistor Circuit
NOISE FILTER TEST
Q
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor. (See Warnings and Instructions on page 3-1)
4. Disconnect the leads to the primary of the power transformer.
5. Using an ohmmeter, check between the terminals as described in the following table.
If incorrect readings are obtained, replace the noise filter.
6. Reconnect all leads removed from components during testing.
7. Reinstall the outer case (cabinet).
8. Reconnect the power supply cord after the outer case is installed.
9. Run the oven and check all functions.
3-15