Electrolux EI30SM55JB Technical & Service Manual page 28

Range microwave oven
Hide thumbs Also See for EI30SM55JB:
Table of Contents

Advertisement

Troubleshooting and Testing
Procedure
Letter
F
SECONDARY INTERLOCK SWITCH TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor. (See Warnings and Instructions on page 3-1)
4. Isolate the switch and connect the ohmmeter to the common (COM.) and normally open
(NO) terminal of the switch. The meter should indicate an open circuit with the door open
and a closed circuit with the door closed. If improper operation is indicated, replace the
secondary interlock switch.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
PRIMARY INTERLOCK SYSTEM TEST
G
DOOR SENSING SWITCH
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor. (See Warnings and Instructions on page 3-1)
4. Isolate the switch and connect the ohmmeter to the common (COM.) and normally open
(NO) terminal of the switch. The meter should indicate an open circuit with the door open
and a closed circuit with the door closed. If improper operation is indicated, replace the
door sensing switch.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
NOTE: If the door sensing switch contacts fail in the open position and the door is closed, the
cooling fan, turntable and oven light will be activated by RY1.
PRIMARY INTERLOCK RELAY (RY2)
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor. (See Warnings and Instructions on page 3-1)
4. Disconnect two (2) wire leads from the male tab terminals of the Primary Interlock Relay.
Check the state of the relay contacts using a ohmmeter. The relay contacts should be
open. If the relay contacts are closed, replace the circuit board entirely or the relay itself.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
Component Test