LG 55UF6800 Service Manual page 17

Hide thumbs Also See for 55UF6800:
Table of Contents

Advertisement

5.5.4. Adj. Command (Protocol)
<Command Format>
START 6E A 50 A LEN A 03 A CMD A 00 A VAL A CS
A STOP
- LEN: Number of Data Byte to be sent
- CMD : Command
- VAL : FOS Data value
- CS : Checksum of sent data
- A : Acknowledge
Ex) [Send: JA_00_DD] / [Ack: A_00_okDDX]
(1) RS-232C Command used during auto-adj.
RS-232C COMMAND
CMD
DATA
ID
wb
00
00
wb
00
10
wb
00
1f
wb
00
20
wb
00
2f
wb
00
ff
Ex) wb 00 00 -> Begin white balance auto-adj.
wb 00 10 -> Gain adj.
ja 00 ff -> Adj. data
jb 00 c0
...
...
wb 00 1f -> Gain adj. complete
*(wb 00 20(start), wb 00 2f(endc)) -> Off-set adj.
wb 00 ff -> End white balance auto adj.
(2) Adjustment Map
- Applied Model : ALL MODELS
Adj.
Command
item
(lower caseASCII)
CMD1
Cool
R Gain
j
G Gain
j
B Gain
j
R Cut
G Cut
B Cut
Medium
R Gain
j
G Gain
j
B Gain
j
R Cut
G Cut
B Cut
Warm
R Gain
j
G Gain
j
B Gain
j
R Cut
G Cut
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
Explanation
Begin White Balance adj.
Gain adj.(internal white pattern)
Gain adj. completed
Offset adj.(internal white pattern)
Offset adj. completed
End White Balance adj.
(internal pattern disappears )
Data Range
Default
(Hex.)
(Decimal)
CMD2
MIN
MAX
g
00
C0
TBD
h
00
C0
TBD
i
00
C0
TBD
TBD
TBD
TBD
a
00
C0
TBD
b
00
C0
TBD
c
00
C0
TBD
TBD
TBD
TBD
d
00
C0
TBD
e
00
C0
TBD
f
00
C0
TBD
TBD
TBD
5.5.5. Adjustment method
5.5.5.1. Auto WB calibration
(1) Set TV in adj. mode using POWER ONNY key
(2) Zero calibrate probe then place it on the center of the
Display
(3) Connect Cable (RS-232C to USB)
(4) Select mode in adj. Program and begin adj.
(5) When adj. is complete (OK Sign), check adj. status pre
mode(Warm, Medium, Cool)
(6) Remove probe and RS-232C to USB cable to complete adj.
▪ W/B Adj. must begin as start command "wb 00 00" , and
finish as end command "wb 00 ff", and Adj. offset if need
5.5.5.2. Manual adj. method
1) Set TV in Adj. mode using POWER ON
2) Zero Calibrate the probe of Color Analyzer, then place it on
the center of LCD module within 10cm of the surface..
3) Press ADJ key -> EZ adjust using adj. R/C -> 7. White-
Balance then press the cursor to the right (KEY►).
(When KEY(►) is pressed 216 Gray internal pattern will be
displayed)
4) One of R Gain / G Gain / B Gain should be fixed at 192, and
the rest will be lowered to meet the desired value.
5) Adj. is performed in COOL, MEDIUM, WARM 3 modes of
color temperature.
** R-fix adjustment
Adjust modes (Cool), Fix the R gain to 210 (default data) and
change the others (G/B Gain ).
- Adjust the R gain more than 210 ( If G gain or B gain is less
than 0 , R gain can adjust more than 210 ) and
change the others ( G/B Gain ).
Adjust two modes (Medium / Warm), Fix the one of R/G/B gain
to 192 (default data) and decrease the others.
▪ If internal pattern is not available, use RF input. In EZ Adj.
menu 7.White Balance, you can select one of 2 Test-pattern:
ON, OFF. Default is inner(ON). By selecting OFF, you can
adjust using RF signal in 216 Gray pattern.
▪ Adj. condition and cautionary items
1) Lighting condition in surrounding area
Surrounding lighting should be lower 10 lux. Try to isolate
adj. area into dark surrounding.
2) Probe location
- PDP : Color Analyzer (CA-100, CA-100+, CA210) probe
should be firmly attached to the Module
- LCD : Color Analyzer (CA-210) probe should be within 10cm
and perpendicular of the module surface (80°~ 100°)
3) Aging time
- After Aging Start, Keep the Power ON status during 5
Minutes.
- In case of LCD, Back-light on should be checked using no
signal or Full-white pattern.
- 17 -
LGE Internal Use Only

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents