Thank you for choosing Aube's non-
programmable
thermostat.
Your
new
electronic thermostat is equipped with a
microprocessor and proportional integral
adaptive
(PIA)
temperature
control
technology for total comfort. Depending on
the selected model, this thermostat has been
designed to control:
A: The Ambient temperature (using an
electric heating system)
AF: The Ambient temperature with Floor
temperature limit (using a floor heating
system to heat the room)
F:
The Floor temperature (floor heating)
NOTE:
This
control
module must
be
mounted on a PB112 Series power base.
The thermostat has an On/Standby switch
making it possible to put the thermostat in
sleep mode when its use is no longer
required (e.g. summer).
Align the bracket tabs on the control module with the
holes located on the power base.
Follow the same procedure for the TH116.
Control module
Power base
NOTE:
Keep the thermostat's air vents clean and free
from obstructions.
NOTE:
The screw cannot be removed completely.

FOR A AND AF MODELS ONLY
At the rear of the control module is a switch that has been
factory-set to the applicable temperature control.
NOTE:
The AF model can be used for all temperature
control types (A, F and AF).
TH116
Public Area
TH113
The GFCI monitors the electrical
flow for any loss of current; if
there is any loss, the thermostat
will cut off power to the heating
system. We recommend you test
the
GFCI
immediately
after
installing the control module, and
once
a
month
thereafter
to
ensure it is operating properly. To
test:
!
Press the TEST button:
• Successful: TEST warn-
ing light is ON and power to heating system is cut
off.
• Unsucessful: The TEST warning light is OFF. Cut
power to heating system from the main power
panel and call customer service.
"
When successful, reset thermostat (STANDBY/ON)
to power heating system.
NOTE:
If the test warning light comes ON during normal
operation, cut power to heating system from the main
power panel and have an electrician verify the installation.
At the rear of the control module are two potentiometers.
These potentiometers act like a temperature lock. Even
when occupants adjust the temperature using the dial on
the front/rear of the control module, the potentiometers
override the dial and maintain the temperature within the
locked-in minimum and maximum range.
A
- ambient temperature
Note: The ambient
F & AF
- floor temperature limit
sensor is not
operational when the
Use a flat tip screwdriver to rotate the potentiometers until
switch is set to I (up).
the notch points to the desired temperature.
The TH113 and TH116 are equipped with a remote input
which allows connection of an optional telephone
controller (CT240) or any other remote control system.
When a command signal is received through this input,
the thermostat automatically lowers its setpoint by 3.5°C.
The LED lights up to indicate the signal's presence
(except for GA and GB models).
Bypass (not available for GA and GB power
The TEST button can be used to bypass the signal for a
2-hour period. The LED goes off to indicate the bypass.
NOTE:
When combined with a GA/GB power base, the
TEST button is used only for GFCI testing. The bypass
function is not available with these power base models.
Models: TH113 and TH116 A / AF / F
Setting
range: 45°F, 59°F to 95°F (7°C, 15°C to 35°C)
Potentiometers: minimum: 41°F to 77°F (5°C to 25°C)
maximum: 59°F to 95°F (15°C to 35°C)
Accuracy: ± 0.9°F (0.5°C)
Storage: -4°F to 120°F (-20°C to 50°C)
Turn the dial to the desired temperature.
TH113: The dial is located on the front of the control
module.
TH116: The dial is located on the rear of the control
module.
The min. position indicates the minimum temperature
setpoint: 45°F (7°C).
Potentiometers
Notch
TH113
AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY
This product is guaranteed against workmanship defects for a one year
period following the initial date of purchase. During this period, AUBE
Technologies Inc. will repair or replace, at our option and without charge,
any defective product which has been used under normal conditions. The
warranty does not cover delivery costs and does not apply to products
poorly installed or randomly damaged following installation. This warranty
cancels and replaces any other manufacturer's express or implied
warranty as well as any other company commitment. AUBE Technologies
Inc. cannot be held liable for related or random damages following the
installation of this product. The defective product as well as the purchase
base):
invoice must be returned to the place of purchase or mailed, prepaid and
insured, to the following address:
Aube Technologies Inc.
705 Montrichard
Saint-Jean-sur-Richelieu, Quebec, Canada J2X 5K8
If you have any questions concerning the TH113 or the TH116
thermostat, call our technical support team at:
Phone:
Fax:
Email:
Monday to Friday from 8:30 AM to 5:00 PM EST.
For more information on our products, visit us at:
Temperature
dial
TH116
Montreal area: (450) 358-4600
Canada / U.S.: 1-800-831-AUBE
(2823)
y(450) 358-4650
service@aubetech.com
www.aubetech.com
01/08/03
920-113-001-00-1-A

Advertisement

loading

Summary of Contents for Aube Technologies TH113

  • Page 1 Accuracy: ± 0.9°F (0.5°C) Storage: -4°F to 120°F (-20°C to 50°C) Turn the dial to the desired temperature. TH113: The dial is located on the front of the control module. TH116: The dial is located on the rear of the control module.
  • Page 2: Installation Instructions

    For a new installation, choose a location about 1.5 m (5 ft.) above the floor. The thermostat must be installed on an inside wall facing the heating system (except for floor heating systems). Avoid locations where there are air drafts (top of staircase, air...

This manual is also suitable for:

Th114Th116 aTh116 fTh116 af