Kenwood DDX7015 Service Manual page 9

Monitor with dvd receiver
Hide thumbs Also See for DDX7015:
Table of Contents

Advertisement

Ref.No.
Application/Function
Q22
P-CONT
Q23
P-ANT switch
Q24
P-CONT
Q25
P-CONT
Q26
BU detection switch
Q27
EXT-AMP switch
Q100
S-MUTE reverse switch
Q200
AM power supply switch
Q201
AM power supply switch
Q300
NOISE switch
Q301
S-MUTE switch
Q460
TV resetting reverse switch
Voltage conversion audio
Q551~554
selector switch
Q600,601
Muting sub-woofer
Q602,604~606
Muting pre-out
Q603
Muting pre-out
Q607
Muting sub-woofer
Q608,610
Muting AVOUT
Q609
Muting AVOUT
Q700
IC700, 701 switching switch
Q702
Muting GSM left audio
Q703
Muting GSM left audio
Q704
FAN5V
For J701
Q705
(optical output connector)
Q706
Muting GSM right audio
Q707
Muting GSM right audio
Q712
Muting BUS
Q713
Muting BUS
Q904~906
Noise canceller
VIDEO UNIT (X35-4332-70)
Ref.No.
Application/Function
IC1
Inverter control IC
IC101
DC/DC converter
IC203
VCOM amplifier
IC301
Timing controller
IC302
AND
IC303
PLL LPF
COMPONENTS DESCRIPTION
Turned ON when Q21 is turned ON.
Turned ON when Q20 is turned ON.
Turned ON when Q25 is turned ON.
Turned ON when BU14V is supplied. Turned OFF when Q22 is turned ON.
Turned ON when BU is detected.
Turned ON when EXT-CONT terminal is L.
Turned ON when momentary power down, when reset, and when S-MUTE is turned ON.
Turned ON when TUNER is selected.
Turned ON when Q200 is turned ON.
Turned ON when IC301QUAL terminal is Hi.
Turned ON when Q100 is turned ON.
Reverses when reset and outputs Hi.
Outputs by converting 5V→8V.
Turned ON when Q607 is turned ON.
Turned ON when Q603 is turned ON.
Turned ON when momentary power down, when reset, and when MUTE_PRE is turned ON.
Turned ON when momentary power down, when reset, and when MUTE_SW is turned ON.
Turned ON when Q609 is turned ON.
Turned ON when momentary power down, when reset, and when MUTE_AVOUT is turned ON.
Controlled by ES_DSP_SW.
Turned ON when momentary power down, when reset, and when MUTE_LEFT is turned ON.
Q702 is turned ON.
MZ_SYS_ON is turned ON. Turned OFF when MZ_SYS_OFF is turned ON.
Turned ON/OFF by 05 signal.
Turned ON when Q707 is turned ON.
Turned ON when momentary power down, when reset, and when MUTE_RIGHT is turned ON.
Turned ON when BUS_MUTE is turned ON.
Turned ON when Q712 is turned ON.
-
Controlling and driving inverter circuit for backlight.
±12V power supply for VCOM amplifier, -12.0V/+18.5V LCD power supply.
VCOM signal amplifier.
LCD module control.
V. SYNC delay buffer.
PLL control LPF (VT voltage control).
DDX7015/7025/7035
DDX7045/7065
Operation/Condition/Compatibility
Operation/Condition/Compatibility
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ddx7025Ddx7045Ddx7065Ddx7035

Table of Contents