3-1. FUNCTION SETTING

3-1-1 INDOOR UNIT

Follow the instructions in the Local Setup Procedure, which is supplied with the remote control,
in accordance with the installed condition.
After the power is turned on, perform the Function Setting on the remote control.
The settings may be selected between the following two: Function Number or Setting Value.
Settings will not be changed if invalid numbers or setting values are selected.
1-1. Setting the Filter sign
Select appropriate intervals for displaying the filter sign on the indoor unit
according to the estimated amount of dust in the air of the room.
If the indication is not required, select "No indication" (03).
Setting Description
(400 hours)
Standard
Long interval
(1000 hours)
(200 hours)
Short interval
No indication
1-2. Setting the Room temperature control for cooling
Depending on the installed environment, correction of the room temperature sensor may be required.
Select the appropriate control setting according to the installed environment.
Setting Description
Standard
Slightly lower control
Lower control
Higher control
1-3. Setting the Room temperature control for heating
Depending on the installed environment, correction of the room temperature sensor may be required.
Select the appropriate control setting according to the installed environment.
Setting Description
Standard
Lower control
Slightly warmer control
Higher control
When using floor console installation, change the setting value to "01".
1-4. Setting the Auto restart
Enable or disable automatic restart after a power interruption.
Setting Description
Enable
Disable
* Auto restart is an emergency function such as for power outage etc.
Do not attempt to use this function in normal operation.
Be sure to operate the unit by remote controller or external input device.
(
Factory setting)
Function Number
Setting Value
11
(
Factory setting)
Function Number
Setting Value
30
(
Factory setting)
Function Number
Setting Value
31
(
Factory setting)
Function Number
Setting Value
40
03-01
00
01
02
03
00
01
02
03
00
01
02
03
00
01