Do you have a question about the PW1850-U-S and is the answer not in the manual?
Questions and answers
paul leslie gordon
March 17, 2025
need a new spray nozzle for P2020 power washer
2 comments:
paul leslie gordon
March 17, 2025
@paul leslie gordon
Mr. Anderson
May 14, 2025
The PowerWasher PW1850-U-S is compatible with standard quick-connect spray nozzles that fit its spray wand. It typically uses 1/4-inch quick-connect nozzles. Common nozzle types include 0°, 15°, 25°, 40°, and a soap nozzle. Always check the PSI rating (up to 1850 PSI) to ensure the nozzles match the pressure rating of the unit.
This answer is automatically generated
Gregg
May 21, 2025
When I pull the trigger on the power washer gun, the motor runs for a couple of seconds and then stops. With the motor off and water from the hose on, water does not come out when i pull the trigger
1 comments:
Mr. Anderson
May 24, 2025
The PowerWasher PW1850-U-S motor running briefly and then stopping, along with no water coming out when the trigger is pulled, can be caused by several issues:
1. Water Supply Problem: If there is insufficient or no water supply to the unit, the motor may shut off to prevent damage. Ensure the garden hose is connected properly, the water source is turned on, and there are no kinks or blockages in the hose.
2. Air in the System: Air trapped in the pump can prevent proper operation. Before turning on the unit, run water through the system (with the unit off and trigger pulled) to remove air.
3. Clogged Nozzle or Filter: A blocked spray nozzle or inlet filter restricts water flow, causing the pressure washer to shut down. Clean the nozzle and inspect the inlet filter for debris.
4. Trigger Gun Malfunction: If the trigger gun is faulty or not engaging properly, it may prevent water from flowing and cause the motor to stop. Check for damage or wear.
5. Pump or Unloader Valve Issue: A stuck unloader valve or a malfunction in the pump can cause pressure buildup or drop, leading to the motor shutting off. These may require inspection or servicing.
6. Electrical Overload or Fault: If the motor is overheating or there's an electrical issue, it may shut off for safety. Check if the unit is plugged into a proper outlet and not using an extension cord too long or thin.
In summary, check water supply, remove air from the system, clean nozzle and filter, inspect the trigger gun, and examine pump components for faults.
This answer is automatically generated
James
March 30, 2025
Where does oring go in nozzle
1 comments:
Mr. Anderson
March 31, 2025
The O-ring in the PowerWasher PW1850-U-S nozzle goes inside the nozzle where it connects to the spray wand or lance. Specifically, it fits into the groove at the base of the nozzle fitting, helping to create a watertight seal between the nozzle and the wand. This prevents leaks and ensures proper water pressure during operation. Make sure the O-ring is seated properly and is not damaged or worn.
Need help?
Do you have a question about the PW1850-U-S and is the answer not in the manual?
Questions and answers
need a new spray nozzle for P2020 power washer
@paul leslie gordon
The PowerWasher PW1850-U-S is compatible with standard quick-connect spray nozzles that fit its spray wand. It typically uses 1/4-inch quick-connect nozzles. Common nozzle types include 0°, 15°, 25°, 40°, and a soap nozzle. Always check the PSI rating (up to 1850 PSI) to ensure the nozzles match the pressure rating of the unit.
This answer is automatically generated
When I pull the trigger on the power washer gun, the motor runs for a couple of seconds and then stops. With the motor off and water from the hose on, water does not come out when i pull the trigger
The PowerWasher PW1850-U-S motor running briefly and then stopping, along with no water coming out when the trigger is pulled, can be caused by several issues:
1. Water Supply Problem: If there is insufficient or no water supply to the unit, the motor may shut off to prevent damage. Ensure the garden hose is connected properly, the water source is turned on, and there are no kinks or blockages in the hose.
2. Air in the System: Air trapped in the pump can prevent proper operation. Before turning on the unit, run water through the system (with the unit off and trigger pulled) to remove air.
3. Clogged Nozzle or Filter: A blocked spray nozzle or inlet filter restricts water flow, causing the pressure washer to shut down. Clean the nozzle and inspect the inlet filter for debris.
4. Trigger Gun Malfunction: If the trigger gun is faulty or not engaging properly, it may prevent water from flowing and cause the motor to stop. Check for damage or wear.
5. Pump or Unloader Valve Issue: A stuck unloader valve or a malfunction in the pump can cause pressure buildup or drop, leading to the motor shutting off. These may require inspection or servicing.
6. Electrical Overload or Fault: If the motor is overheating or there's an electrical issue, it may shut off for safety. Check if the unit is plugged into a proper outlet and not using an extension cord too long or thin.
In summary, check water supply, remove air from the system, clean nozzle and filter, inspect the trigger gun, and examine pump components for faults.
This answer is automatically generated
Where does oring go in nozzle
The O-ring in the PowerWasher PW1850-U-S nozzle goes inside the nozzle where it connects to the spray wand or lance. Specifically, it fits into the groove at the base of the nozzle fitting, helping to create a watertight seal between the nozzle and the wand. This prevents leaks and ensures proper water pressure during operation. Make sure the O-ring is seated properly and is not damaged or worn.
This answer is automatically generated