Sensor Type Selection; Cct-05, Electrical Features (Specifications) - Omega CCT-05 Series User Manual

Frequency input signal conditioners
Table of Contents

Advertisement

SENSOR TYPE SELECTION

This signal conditioner can connect to standard
sensors such as PNP, NPN, Namur or ac signals.
See the Connections Section.
The signal conditioner provides two excitation
voltages for the sensors, 24 Vdc for PNP or NPN
sensors and 8.2 Vdc for NAMUR sensors. Table 4
indicates which jumpers must be selected for each
type of sensor. The jumpers are located on the "MP"
input board. See Fig. 8.
CCT-05 ELECTRICAL FEATURES
INPUT
SIGNAL TYPE
FREQUENCY
AUXILIARY POWER SUPPLY
OUTPUT
0 to 20 mA or 4 to 20 mA
0 to 10 Vdc
ACCURACY
RESPONSE TIME
GALVANIC ISOLATION
GENERAL SPECIFICATIONS
RIPPLE
BAND PASS
STORAGE TEMPERATURE
OPERATING TEMPERATURE
TEMPERATURE COEFFICIENT
STANDARD POWER SUPPLY
POWER CONSUMPTION
TEST VOLTAGE
Sensor type selection
(Selector A)
NAMUR
NPN/PNP (3 wires)
NPN (Open collector)
PNP (Open collector)
Vac 100
Vac 100
PNP, NPN, Namur, Vac
Min. 10 Hz.
Max. 40 KHz.
+24 Vdc @ 25 mA. for PNP, NPN.
8.2 Vdc for Namur
R
< 600
max. 22 mA ±3%
L
R
> 1000
max. 11 V ±3%
L
0.2 % FS
250 mS
Input, Output and Power Supply are all isolated
to 2 kVeff
50 Hz/1 m.
.
0.5 %
1.5 Hz (-3 dB)
-30° to +80°C
-10° to +60°C
0.015 %/°C
115 Vac (±10%) 50/60 Hz
1.5 VA
4 kVeff. 50 Hz/1m.
7
TABLE 4
close
jumper
10 & 9
10
10 & 7
10 & 8
10
-----

Advertisement

Table of Contents
loading

Table of Contents