Installing The Meter; Setting The Jumpers; Installation Environment; Timer Input Logic Jumper - Omega Engineering PTC900 User Manual

Panel-mount programmable timer and real-time clock
Table of Contents

Advertisement

1.0 I
NSTALLING THE
Installation
The meter meets NEMA 4X/IP65 requirements for indoor use when properly
installed. The meter is intended to be mounted into an enclosed panel. Prepare
the panel cutout to the dimensions shown. Remove the panel latch from the
2.0 S
ETTING THE
To access the jumpers, remove the meter base from the meter case by firmly
squeezing and pulling back on the side rear finger tabs. This should lower the
latch below the case slot (which is located just in front of the finger tabs). It is
recommended to release the latch on one side, then start the other side latch.
Warning: Exposed line voltage exists on the circuit boards. Remove
all power to the meter and load circuits before accessing inside of
the meter.
Main
Circuit
Board
SRC
SNK
TIMER
INPUT
JUMPER
M
meter. Slide the panel gasket over the
rear of the meter to the back of the
bezel. The meter should be
installed fully assembled.
Insert the meter into the
panel cutout.
J
UMPERS
USER
INPUT
JUMPER
SRC
SNK
ETER
While holding the meter in place, push the panel latch over the rear of the
meter so that the tabs of the panel latch engage in the slots on the case. The
panel latch should be engaged in the farthest forward slot possible. To achieve
a proper seal, tighten the latch screws evenly until the meter is snug in the panel
(Torque to approximately 7 in-lbs [79N-cm]). Do not over-tighten the screws.

Installation Environment

The meter should be installed in a location that does not exceed the operating
temperature and provides good air circulation. Placing the meter near devices
that generate excessive heat should be avoided.
The bezel should only be cleaned with a soft cloth and neutral soap product.
Do NOT use solvents. Continuous exposure to direct sunlight may accelerate
the aging process of the bezel.
Do not use tools of any kind (screwdrivers, pens, pencils, etc.) to operate the
keypad of the meter.

Timer Input Logic Jumper

One jumper is used for the logic state of both timer inputs. Select the proper
position to match the input being used.
User Input Logic Jumper
One jumper is used for the logic state of all user inputs. If the user inputs are
not used, it is not necessary to check or move this jumper.
JUMPER SELECTIONS
The
6
PANEL CUT-OUT
indicates factory setting.