Ptc901 Application; Real-Time Clock Synchronization Network; Serial Communication Parameters - Omega Engineering PTC900 User Manual

Panel-mount programmable timer and real-time clock
Table of Contents

Advertisement

Setpoint (Alarm) Parameters
6-SPt
DISPLAY
PARAMETER
ASM-n
SETPOINT ASSIGNMENT
ACt-n
SETPOINT ACTION
OUt-n
OUTPUT LOGIC
ON-n
SETPOINT ON (A)
SETPOINT ON (B)*
SP-n
SETPOINT ON VALUE (A)
SETPOINT ON VALUE (B)*
OFF-n
SETPOINT OFF (A)
SETPOINT OFF (B)*
SPOF-n
SETPOINT OFF VALUE (A)
SETPOINT OFF VALUE (B)*
tOUt-n
TIME-OUT VALUE (A)
TIME-OUT VALUE (B)*
DAILY ON OCCURRENCE (A)
DAILY ON OCCURRENCE (B)*
DAILY OFF OCCURRENCE (A)
DAILY OFF OCCURRENCE (B)*
TIMER STOP
TIMER/COUNTER AUTO RESET
OUTPUT RESET W/DISPLAY RESET
SETPOINT ANNUNCIATOR
POWER-UP STATE

Serial Communication Parameters

7-SrL
DISPLAY
PARAMETER
bAUd
BAUD RATE
dAtA
DATA BITS
PAr
PARITY BIT
Addr
METER UNIT ADDRESS
Abbr
ABBREVIATED PRINTING
REAL-TIME CLOCK PRINT FORMAT
OPt
PRINT OPTIONS
t-dSP
TIMER DISPLAY
C-dSP
CYCLE COUNTER DISPLAY
rtC-d
RTC DATE DISPLAY
rtC-t
RTC TIME DISPLAY
spNt
SETPOINT VALUES
SPNtOF
SETPOINT OFF/ TIME-OUT VALUES
* See Module 2, Exchanging Parameter Lists, for details on programming this value.
Shaded areas are model dependent.
Shaded areas are model dependent.

PTC901 Application

A big application request has always been for
Real-Time Clocks to display time throughout the
plant. The challenge has been to keep all the
various clock locations synchronized with the
right time. With the new PTC901 Timer/Real-
Time Clock this problem is history. You can install
up to a maximum of 32 units. Simply select one of
the units in the system as the host and the balance
are programmed as slaves. The host will send out
a synchronization pulse every hour to correct the
time on any clock unit wired in the system.
SP-1
FACTORY
FACTORY
USER SETTING
SETTING
SETTING
NONE
NONE
LAtCH
LAtCH
NOr
NOr
VALUE
VALUE
VALUE
VALUE
000000
000000
000000
000000
VALUE
VALUE
VALUE
VALUE
000100
000100
000100
000100
Mon-Fri
Mon-Fri
Mon-Fri
Mon-Fri
Mon-Fri
Mon-Fri
Mon-Fri
Mon-Fri
NO
NO
NO
NO
NO
NO
NOr
NOr
FACTORY
USER SETTING
SETTING
9600
7
Odd
00
NO
YES
YES
NO
NO
NO
NO
NO

Real-Time Clock Synchronization Network

28
SP-2
SP-3
FACTORY
USER SETTING
SETTING
NONE
LAtCH
NOr
VALUE
VALUE
000000
000000
VALUE
VALUE
000100
000100
Mon-Fri
Mon-Fri
Mon-Fri
Mon-Fri
NO
NO
NO
NOr
Real-Time Clock Parameters
8-rtC
DISPLAY
PARAMETER
dSP-t
TIME DISPLAY FORMAT
dSP-d
DATE DISPLAY FORMAT
Ch-dSt
AUTO TIME CHANGE FOR D.S.T.
SyNC
SYNCHRONIZATION UNIT TYPE
CAL
CALIBRATE REAL-TIME CLOCK
OFFSEt
RTC CALIBRATION OFFSET VALUE
Factory Service Parameters
9-fCS
DISPLAY
PARAMETER
d-LEV
DISPLAY INTENSITY LEVEL
SP-4
FACTORY
USER SETTING
USER SETTING
SETTING
NONE
LAtCH
NOr
VALUE
VALUE
000000
000000
VALUE
VALUE
000100
000100
Mon-Fri
Mon-Fri
Mon-Fri
Mon-Fri
NO
NO
NO
NOr
FACTORY
USER SETTING
SETTING
12-59p
12-31
N0
sLAVE
00
FACTORY
USER SETTING
SETTING
3