Download Print this page

Omega Speaker Systems Advance 300 Calibration Instructions page 2

Omega treadmill manual calibration instructions

Advertisement

Manual and Auto Calibration Instructions
For Models: Advance 205 | T20 | T30 | T40 | 2.0T | 3.0T | 4.0T | 5.0T | Free Spirit 200 | Free Spirit 300 | Free
Spirit 400 | 1.1T | 2.1T | 3.1T | 4.1T | 5.1T
F1
10%
10
%
9
%
8
%
7
%
Distance / Laps
6
%
5
%
4
Manual
Intervals
Rolling
Weight Loss
%
Hill Climb
Race
THR Zone
Custom 1
3
%
2
%
1
START
%
SELECT
SELECT
INCLINE
SPEED
Step One | Entering the Engineering Mode
1
Turn the treadmill power to ON.
2
Place the safety key in position on the console.
3
Simultaneously press and hold (for about five seconds) the following buttons:
For Models 3.0T | 4.0T | 5.0T | Free Spirit 200, 300, 400: The "10%" and "10mph" buttons.(F1)
All other Models: The incline "+" (s) and speed "-" (t) buttons.(F1 & F2)
4
The console should beep three times and ENG0 (EN90) should be displayed.
This indicates you are in the engineering menu.
Note: if ENG0 (EN90) is not displayed, but ENG (EN9) is displayed with another number at the end, you are still in the
engineering menu. Use the "+" (s) or "-" (t) buttons to navigate to the correct menu. See following instructions.
Step Two | Manual Calibration
1
Press the speed "+" (s) or "-" (t) button until ENG1 (EN91) is displayed.
2
Press and hold the "Start" button for about three seconds to select.
For Models 4.1T | 5.1T: Press and hold the "Select" button for about three seconds to select.
Do NOT stand on the running belt when calibrating. Use the guide rails instead.
WARNING
3
Press the "Start" button to begin manual calibration. The Running belt should begin moving.
4
The readout in the speed window will indicate the start speed of the unit. This should be 0.5mph (+ or - .05). If the
speed is not within the proper start range, adjust the speed cube (F3) until the speed window (F2) readout is correct.(See
note below)
Note: The speed cube is located on the Motor Control Board. It is blue with a small yellow screw. (F3) When adjusting the
speed cube, turn the screw right to increase the speed and left to decrease the speed. Use small increments as the speed
cube is sensitive and will respond to each change. DO NOT PUSH DOWN HARD ON THE SCREW.
5
Once the speed readout is at the proper setting, press and hold the "Stop" button for about three seconds to return to
the engineering menu. Proceed to the following instructions to Auto Calibrate the unit.
Step Three | Auto Calibration
After following the steps above you will have one step left to complete the calibration process.
Note: If you are not in the engineering menu, follow steps 1-4 from Entering the Engineering Mode.
1
Press the speed "+" (s) or "-" (t) buttons until ENG2 (EN92) is displayed.
2
Press and hold the "Start" button for about three seconds to select.
For Models 4.1T | 5.1T: Press and hold the "Select" button for about three seconds to select.
3
Press the "Start" button to begin.
The running belt will begin moving and will automatically begin the auto-calibration sequence to properly set and store the
speed values. Upon successful calibration there will be four beeps and it will automatically exit the Engineering Mode and will
return to the original screen. The whole process will typically take about two minutes.
Manual and Auto Cal _rev1.5 | 08/17/07 JHP
10mph
10
mph
9
mph
8
mph
7
mph
Time
6
mph
5
mph
Hill Run
4
mph
Custom 2
3
mph
2
mph
1
STOP
mph
TRANSFORMER
F2
SPEED CUBE
F3

Advertisement

loading

This manual is also suitable for:

Rt1T51T52T53T54T605 ... Show all