Product Information; Specifications - Omega Engineering 8 Channel Thermocouple USB Data Acquisition Module TC-08 User Manual

8 channel thermocouple usb data acquisition module
Table of Contents

Advertisement

Product information

2
2.1

Specifications

Resolution
Thermocouple types
Number of input channels
Conversion time - per active channel
Conversion time - CJC
Uncalibrated accuracy
Full scale input
Common mode range
Overvoltage protection
Input impedance
Input connectors
Output connector
Power requirements
Environmental conditions
Note: The resolution and accuracy depend upon the thermocouple type and the
temperature range. Below is a list of the thermocouples and temperature ranges
supported by the USB TC-08.
CJC
Type B
Type E
Type J
Type K
Type N
Type R
Type S
Type T
Actual measurable range
-5°C to 70°C
20°C to 1820°C (CJC must be
>20°C)
-270°C to 910°C
-210°C to 1200°C
-270°C to 1370°C
-270°C to 1300°C
-50°C to 1760°C
-50°C to 1760°C
-270°C to 400°C
Product information
20 bits (16.25 NFR)
B,E,J,K,N,R,S,T
8
100 ms
100 ms
The sum of ±0.2% and ±0.5°C
±70 mV
±7.5 V
±30 V
2 M
W
8 x miniature thermocouple
USB upstream connector
No power supply required
0 to 50°C, 25% to 75% humidity
Quoted accuracy over 20 - 30°C
NOT water-resistant
Theoretical ranges
N/A
0°C to 1820°C
-270°C to 1000°C
-210°C to 1200°C
-270°C to 1370°C
-270°C to 1300°C
-50°C to 1760°C
-50°C to 1760°C
-270°C to 400°C
5