Program Controller' Mode; Display Time; Display Option; Rate Time-Base - Omega Engineering DPS3301 Series User Manual

Wall-mount programmable temperature monitor
Table of Contents

Advertisement

'PROGRAM CONTROLLER' MODE

Display Time

On entering Program Controller mode, the very first step lets you
program is the display time. This determines the length of time (in
seconds) that any VALUE is displayed before message, such as
'PROCESS' is flashed.
The unit will first show 'dSPLy t' (for Display Time), and then the
current setting in seconds. Use '^DIGv' and '<DIG>' key to set the
desired display time. Push 'SETUP' key following the selection.

Display Option:

This is indicated by the display briefly reading 'dSP OP
display option) and then the currently selected Option. Use '^DIGv'
key to step thru various options. Once the desired option has been
selected, push 'SETUP' key to enter it and go on to set Display Time.
Display Mode
PROCESS
SETPOINT DEVIATION
INSTANTANEOUS RATE
PROCESS HIGH
PROCESS LOW
ELAPSED TIME
TIMER 1 COUNT DOWN
TIMER 2 COUNT DOWN
SCAN

Rate Time-Base:

This step is for programming time-base for calculation of Rate. Units
of time-base are seconds. Again, the active digit will be flashing.
Message displayed before the value is "rATE tb:. To change the
value, push ^v key. To activate another digit for change, use <DIG>
key. On finishing, push SETUP key.
t'
(for
Display shows
PrOCESS
SP. DEVN
In. rAtE
Pr. HIGH
Pr. LO
ELPSd. T
tr1. Cnt
tr1. Cnt
SCAn
Page
10
Description
Displays process value.
Displays setpoint deviaition.
Displays Instantaneous rate value.
Displays process' highest reading
Displays process' lowest reading
Displays elapsed time.
Display Timer 1 count down value
Display Timer 2 count down value
Scans through all the above parameters