FIG E: FLUE SYSTEM REQUIREMENTS
3000
1000 min. if clear
Any nearby
within 3000 of
structure
flue top
NOTE : Dimensions are in millimetres
A.
THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED IN COMPLIANCE WITH AS/NZS
2918:2001 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING CODE OR
CODES.
B.
APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL COMPLY WITH THE
REQUIREMENTS OF AS/NZS 4013 WHERE REQUIRED BY THE REGULATORY AUTHORITY I.E.
THE APPLIANCE SHALL BE IDENTIFIABLE BY A COMPLIANCE PLATE WITH THE MARKING
"TESTED TO AS/NZS 4013"
C.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY
THE TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED
FOR COMPLIANCE WITH AS/NZS 4013
D.
MIXING OF APPLIANCE OR FLUE SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR
MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN
HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS CONSIDERED, THE MANUFACTURER
SHOULD BE CONSULTED IN THE FIRST INSTANCE.
E.
CRACKED AND BROKEN COMPONENTS E.G. GLASS PANELS OR FIRE BRICKS, MAY RENDER
THE INSTALLATION UNSAFE.
IF A WATERBOOSTER IS FITTED:
NOTE: A WATER BOOSTER CAN ONLY BE FITTED TO THE "WET" VERSION OF THIS UNIT
WHEN IN CLEAN AIR ZONES (CHECK LOCAL COUNCIL REGULATIONS)
A. DO NOT CONNECT TO AN UNVENTED HOT WATER SYSTEM
B. INSTALL IN ACCORDANCE WITH AS 3500.4.1 OR NZS 4603 AND THE APPROPRIATE
REQUIREMENTS OF THE RELEVANT BUILDING CODES.
SEISMIC RESTRAINT
Secure the heater base to the hearth or sub-framing with Dynabolts or similar.
Follow local Council's Specifications.
Install-MONTE_BASE - SEP_2015.doc
3000
or less
3000
or less
MINIMUM HEIGHT OF FLUE SYSTEM EXIT

IMPORTANT INFORMATION

www.yunca.co.nz
(not to scale)
More than 3000
3000
More than 3000
3000
1000 min. if clear
within 3000 of
flue top
Increase from
1000 min. until
clear within
3000 of flue top
Page 4 of 4