Sony MVC-CD300 Service Manual page 64

Hide thumbs Also See for MVC-CD300:
Table of Contents

Advertisement

6-5.
Read (CD) Adjustment
1)
Stand the BU adjustment jig in the upright position.
2)
Connect a jitter meter to the BU adjustment jig.
(Refer to section "4-2. Jitter Meter of "4. Equipment
Connection.)
3)
Insert the test CD (SCD-2700).
4)
Click the [START] button of the [Read (CD)Adjust] on the
Adjustment Menu screen of the "Dencho for DDX-G2100".
(Fig.6-5-1)
5)
The following adjustments and checks are performed
automatically in order. The asterisk marks "***" appears in
the column in which the adjustment and check is in progress.
When the adjustments and checks are complete, "OK " is
displayed.
Adjust FE
DPP Balance
TE Gain Offset
Focus gain Tracking Gain
Focus Bias RF
MPP Out Adjust
RF Gain
RF Jitter Check (Note)
Note: During the RF Jitter Check mode, check that the jitter is 8ns or
less with the jitter meter and click the [OK] button. (Fig.6-5-1)
Fig. 6-5-1
6)
Turn off the power of the BU adjustment jig and turn on again.
7)
Clich the "Renewal" button on the Adjustment Menu screen.
6-6.
Write (CDR) Adjustment
1)
Stand the BU adjustment jig in the upright position.
2)
Connect a jitter meter to the BU adjustment jig.
(Refer to section "4-2. Jitter Meter of "4. Equipment
Connection.)
3)
Insert the 8 cm CD-R (MCR-156A)
Note: The maximum number of times that the CD-R can be used in
the "Write (CDR) Adjustment" is about 10 times only.
4)
Click the [START] button of the [Write (CDR) Adjust] on the
Adjustment Menu screen of the "Dencho for DDX-G2100".)
5)
The following adjustments and checks are performed
automatically in order. The asterisk marks "***" appears in
the column in which the adjustment and check is in progress.
When the adjustments and checks are complete, "OK " is
displayed.
Jump Adjust
Adjust WFB
ATER Check
Focus Bias ATIP
Read Asymmetry After ATER
Self RF Jitter Check (Note)
Seek Check
Shock Level Adjust
Note: During the Self RF Jitter Check mode, check that the jitter is
8ns or less with the jitter meter and click the [OK] button. (Fig.6-
6-1) Check the jitter value within 4 seconds after this indication
appears.
6)
Turn off the power of the BU adjustment jig and turn on again.
7)
Click the "Renewal" button on the Adjustment Menu screen.
— 19 —