ADJUSTMENT PROCEDURE FOR
R1119
& RllZO cont.:
5.6.
ADJUSTMENT OF 600 kHz GENERATOR.
5.6.1.
Set the MODE SWITCH to pos. A3J.
5.6.2.
Connect the diode probe to TP5.
5.6.3.
Adjust
L1002 for max. deflection
on the
TP-meter (approx.
IV).
5.7.
ADJUSTMENT OF BFO CR1120 only).
5.7.1.
Set the CLARIFIER to its
center posi-
tion.
5.7.2.
Set the MODE SWITCH to Al.
5.7.3.
Set the FILTER SWITCH to WIDE.
5.7.4.
Connect the frequency
counter to TP6.
5.7.5.
Remove the BFO button.
5.7.6.
Adjust
the potentiometer
to 600,000 Hz.
5.7.7.
Mount the button with dot to dot,
to
indicate
the center position.
5.8.
ADJUSTMENT OF
16
MHz GENERATOR.
5.8.1.
Enter fRx
:
11111
kHz to the KEYBOARD,
(press
1
and C simultaneously)
and exe-
cute 5.2.
5.6.2.
Connect the diode probe to TP4.
5.8.3.
Adjust
LlOOl
to max. voltage
(approx.
2V).
5.9.
ADJUSTMENT OF IF AMPLIFIER DETECTOR.
5.9.1.
Connect the signal
generator
to TP7
through a
10
nF capacitor,
execute
5.2.2.,
5.2.3.,
5.2.4.,
5.2.5.,
5.2.6.,
set the signal
generator
to fG
q
599 kHz
and VG z
10
mV.
5.9.2.
Set MODE SWITCH to A3J.
5.9.3.
Slowly
reduce
VG until
noise starts
to
dim the AF tone; then increase
VG 20 dB.
5.9.4.
Connect voltmeter
to HEADPHONES via a
screened cable,
and adjust
AF GAIN so
that the meter reads 0 dB in the 1V
AC range.
5.9.5.
Adjust L805 for max. meter reading and
at the same time keep this
on 0 dB by
reducing
AF GAIN.
5.9.6.
Set AGC SWITCH to OFF.
5.9.7.
Reduce RF GAIN until
meter reading
again is 0 dB in the 1V range.
5.9.8.
Adjust
L801 for max. meter reading and
at the same time keep this
on 0 dB by
reducing
RF GAIN.
5.10.
ADJUSTMENT OF IF FILTER.
5.10.1.
Execute 5.2. with fG = 600,O kHz,
VG
=
VG max.
&
fRx
= 11111
kHz.
5.10.2.
Connect the signal
generator
to TP7
through a
10
nF capacitor.
5.10.3.
Set the MODE SWITCH to A3H.