Defrosting Cycle
1. Total comp. work time
2. Comp. work rate
3. RT temperature
4. Total door open time
1. Conditions to start defrosting cycle
1) Total comp. work time : 6, 8, 10 hours
2) Comp. work rate (by the 2 hours) : over 65%
3) Total door open time : 3 minutes
(Any door - F or R - open time is over 3 minutes.)
4) Total time of [comp. ON + comp. OFF] : 60 hours
5) Ambient temperature : over 35
6) Any error mode : R1, F1, D1, F3, RT/S, Door-switch
2. Conditions to start defrosting mode
1) The mode starts in the following conditions ;
!
Any error happens when total comp. work time is 6 or 8 or 10 hours.
@
Comp. work rate by the 2 hours is over 65%.
#
Total door open time is over 3 minutes.
(Any door - F or R - open time is over 3 minutes.)
Ambient temperature is over 35 .
2) Defrosting mode starts unconditionally as long as total comp. work time is 10 hours,
even if the above conditions( ~$) are not satisfied.
3) Defrosting mode starts immediately as long as total time of [comp. ON + comp. OFF] is
over 60 hours, even if the above 1) and 2) conditions are not satisfied.
Downloaded from Fridge-Manual.com Manuals
INPUT
CONTENTS
C
C
!
Control Object
1. Defrosting Mode
23
OPERATION AND FUCTIONS
REMA
RKS