Download Print this page

Omega DP6-MLPS1 Instruction Sheet

Omega products, inc power supply user manual

Advertisement

Quick Links

DP6-M M LPS1

Power Supply

M4533-0607
INSTRUCTION
SHEET
Shop online at: omega.com e-mail: info@omega.com
For latest product manuals: omegamanual.info
UL Recognized Component,
File # E313607
DESCRIPTION
The Model DP6-MLPS1 is a +12 VDC power supply designed to attach to
the rear of the DP63000x Series. The DP6-MLPS1 can be powered from an 85-
250 VAC source.
Caution: The maximum output current of the DP6-MLPS1 is 400 mA. Check the
specifications of the specific counter(s)/indicators(s) and sensors(s) being
used to ensure that total current requirements do not exceed 400 mA.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
CAUTION: Read complete instructions prior
to installation and operation of the unit.
DIMENSIONS In inches (mm)
CAUTION:
Risk of electric shock.
PROVIDES +12 VDC POWER FOR THE DP63000x SERIES
12 VDC OUTPUT @ 400 mA
EASILY ATTACHED TO BACK OF DP63000x

SPECIFICATIONS

1. POWER REQUIREMENTS: 85-250 VAC, 50/60 Hz, 14 VA.
2. POWER OUTPUT: +16 VDC max @ 4 mA
11.5 VDC min @ 400 mA
3. ENVIRONMENTAL CONDITIONS:
Operating Temperature: 0 to 60°C
Storage Temperature: -30 to 75°C
Operating and Storage Humidity: 85% max. (non-condensing) from 0°C
to 50°C.
Altitude: Up to 2000 meters
4. CERTIFICATIONS AND COMPLIANCES:
SAFETY
UL Recognized Component, File # E313607, UL 61010-1, CSA C22.2
No. 61010-1
Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.
Output meets Class 2 power requirements per UL 1310.
IEC 61010-1, EN 61010-1: Safety requirements for electrical
equipment for measurement, control, and laboratory use, Part 1.
ELECTROMAGNETIC COMPATIBILITY
Emissions and Immunity to EN 61326: Electrical Equipment for
Measurement, Control and Laboratory use.
Immunity to Industrial Locations:
Electrostatic discharge
Electromagnetic RF fields
Fast transients (burst)
Surge
RF conducted interference
Voltage dip/interruptions
Emissions:
Notes:
1. Criterion A: Normal operation within specified limits.
2. Criterion B: Temporary loss of performance from which the unit self-
recovers.
5. CONSTRUCTION: High impact black plastic. Mounting hardware
included. Installation Category II, Pollution Degree 2.
6. CONNECTION: Two position terminal block which accepts one 14 AWG
wire (torque terminal screws to 5 inch-lbs. [0.56 N-m]).
7. WEIGHT: 2 oz (47 g)
EN 61000-4-2
Criterion A
4 kV contact discharge
8 kV air discharge
EN 61000-4-3
Criterion A
10 V/m
EN 61000-4-4
Criterion A
2 kV power
1 kV signal
EN 61000-4-5
Criterion B
1 kV L-L,
2 kV L&N-E power
1 kV signal
EN 61000-4-6
Criterion A
3 V/rms
EN 61000-4-11
Criterion A
0.5 cycle
EN 55011
Class B
LP0696X

Advertisement

loading

Summary of Contents for Omega DP6-MLPS1

  • Page 1: Power Supply

    DESCRIPTION The Model DP6-MLPS1 is a +12 VDC power supply designed to attach to the rear of the DP63000x Series. The DP6-MLPS1 can be powered from an 85- 250 VAC source. Caution: The maximum output current of the DP6-MLPS1 is 400 mA. Check the specifications of the specific counter(s)/indicators(s) and sensors(s) being used to ensure that total current requirements do not exceed 400 mA.
  • Page 2: Troubleshooting

    Installation Procedure The DP6-MLPS1 is shipped with all the necessary hardware to mount to the rear of an installed DP63000x. Refer to the instructions that correspond to your unit for proper installation.
  • Page 3 Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification.
  • Page 4 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors...

This manual is also suitable for:

Rhxl-3sd