Toyoset Omni 230 Operation And Maintenance Instructions

Toyoset Omni 230 Operation And Maintenance Instructions

Portable kerosene heater
Hide thumbs Also See for Omni 230:

Advertisement

Omni 230 Type C_US.qxd 14.8.1 13:15 ページ A
OPERATION AND MAINTENANCE INSTRUCTIONS
Omni 230
MODEL
IMPORTANT
READ AND UNDERSTAND INSTRUCTIONS BEFORE USING HEATER.
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
This heater is designed to be used at altitudes up to 1,300m above sea level. Consult with your dealer otherwise.
SAFETY TIPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
FUEL GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . 5
COMPONENT PARTS . . . . . . . . . . . . . . . . . . . . . . 5
PORTABLE KEROSENE HEATER
(TYPE C)
CONTENTS
ASSEMBLY AND OPERATION . . . . . . . . . . . . . . . 6
CARE AND MAINTENANCE . . . . . . . . . . . . . . . . . 11
REPLACEMENT OF PARTS . . . . . . . . . . . . . . . . 12
STORAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . 16

Advertisement

Table of Contents
loading

Summary of Contents for Toyoset Omni 230

  • Page 1: Table Of Contents

    Omni 230 Type C_US.qxd 14.8.1 13:15 ページ A PORTABLE KEROSENE HEATER OPERATION AND MAINTENANCE INSTRUCTIONS Omni 230 MODEL (TYPE C) IMPORTANT READ AND UNDERSTAND INSTRUCTIONS BEFORE USING HEATER. RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. This heater is designed to be used at altitudes up to 1,300m above sea level. Consult with your dealer otherwise.
  • Page 2: Safety Tips

    TOYOTOMI, the leader in kerosene (paraffin) heater techonlogy, has tested and refined the Omni 230 to assure you of long-term safety and satisfaction. Please study the following instructions, use and care for your heater carefully, and it will serve you well for many years.
  • Page 3 Omni 230 Type C_US.qxd 14.8.1 13:15 ページ 2 3. DO NOT operate heater without protective guards completely attached. 4. DO NOT use heater to heat or boil water or as a cooking appliance. DO NOT place cooking utensils, tea kettles or any other object on top of heater while in operation.
  • Page 4: Fuel Guide

    Omni 230 Type C_US.qxd 14.8.1 13:15 ページ 3 FUEL GUIDE The Omni 230 is designed for use with high-quality kerosene (paraffin) only. Use of low-quality kerosene (paraffin) will cause wick performance to drop, leading to “Iow flame” and “odor problem” conditions.
  • Page 5: Operating Controls And Features

    Omni 230 Type C_US.qxd 14.8.1 13:15 ページ 4 OPERATING CONTROLS AND FEATURES 1. White Clean Heat Chamber 7. Heat Chamber Handle (Inside) 3 . Wick Adjuster Knob 2 . Wick Life Extender 6. Manual Shutoff 5. Fuel Gauge 4. Fuel Tank Cap 1.
  • Page 6: Specifications

    Omni 230 Type C_US.qxd 14.8.1 13:15 ページ 5 SPECIFlCATlONS TOYOSET Portable Kerosene (paraffin) Heater Model Omni 230 Heat rating 23,000 BTU/h (5,820 kcal/h) Fuel tank capacity 7.5 L Burning time/tank* 12-16 Hours Size (W x H x D) 440 x 583 x 440 mm Weight 10.7kg...
  • Page 7: Assembly And Operation

    Omni 230 Type C_US.qxd 14.8.1 13:15 ページ 6 ASSEMBLY AND OPERATlON lNSPECTlON AND ASSEMBLY NOTE: Save the shipping carton and packing materials for future storage of your heater. 1. REMOVE PACKING MATERIALS Remove all packing materials from your heater and install the guard as follows: CAUTION: Risk of fire.
  • Page 8 Omni 230 Type C_US.qxd 14.8.1 13:15 ページ 7 FUELING WARNING: Use only clean Kerosene (paraffin). NEVER use gasoline (petrol) or other flammable liquids. ALWAYS extinguish heater before refill heater fuel tank. Fuel heater outside the living area. 1. lnsert the straight tube of the manual fuel siphon into the kerosene (paraffin) container.
  • Page 9 Omni 230 Type C_US.qxd 14.8.1 13:15 ページ 8 LIGHTING NOTE: When you first use your new heater, ignite it out of the living area of your house, either in a garage or an outside area protected from strong drafts. Burn it for about 15 minutes to remove all of the protective oil present on the burner parts.
  • Page 10 Omni 230 Type C_US.qxd 14.8.1 13:15 ページ 9 ADJUSTING THE FLAME 1. After lighting, wait for the heat chamber to reach operating temperature. This will take ten-fifteen minutes, after which the flame will be visible through the mica window. 2. CHECK THE FLAME LENGTH Look at the flame and check its length.
  • Page 11 Omni 230 Type C_US.qxd 14.8.1 13:15 ページ 10 When the wick adjuster knob is removed, the wick life extender control can be seen Wick heigh adjuster knob (Wick life extender control) to contain 3 sequential holes marked 1 , 2 and 3. By pulling out and turning the control dial counterclockwise, the stem pin of the adjuster can be moved from 1 to 2 and to 3 position as required.
  • Page 12: Care And Maintenance

    Omni 230 Type C_US.qxd 14.8.1 13:15 ページ 11 CARE AND MAINTENANCE As with any good appliance, preventive as well as corrective maintenance is occasionally required. Please read the following section carefully in order to enjoy the greatest benefits from your heater.
  • Page 13: Replacement Of Parts

    Omni 230 Type C_US.qxd 14.8.1 13:15 ページ 12 CLEANING THE HEATER 1. Cleaning the outer cover and the fuel tank. Wipe the surface of the outer cover and the fuel tank with a soft cloth. Stains can be removed with a cloth and a mind soapy solution.
  • Page 14 Omni 230 Type C_US.qxd 14.8.1 13:15 ページ 13 3. Remove the four (4) wing nuts around the wick adjuster. Lift the wick adjuster off the heater while moving it slightly back and forth. 4. Slide two fingers between the wick and the silver wick sleeve attached to the wick adjuster.
  • Page 15 Omni 230 Type C_US.qxd 14.8.1 13:15 ページ 14 9. Tighten the four (4) wing nuts around the wick adjuster. 10. Turn the wick adjuster knob to be sure the wick moves smoothly up and down. AFTER REPLACING THE WICK, CHECK THE OPERATlON OF THE AUTOMATlC EXTINGUISHER.
  • Page 16: Storage

    Omni 230 Type C_US.qxd 14.8.1 13:15 ページ 15 REPLACING THE MICA WINDOW WARNING: Before replacing the mica window, allow heater to cool completely. 1. Remove screw from the mica window frame and lift mica window off. 2. Align notch in mica window with hole on mica window frame.
  • Page 17: Troubleshooting

    Omni 230 Type C_US.qxd 14.8.1 13:15 ページ 16 TROUBLESHOOTING PROBLEM CAUSE SOLUTlON PAGE Wick fails to ignite Out of fuel Check fuel gauge; add fuel if necessary. Electrode does not spark Check wire connections. Replace batteries. Replace igniter unit, if necessary.
  • Page 18 Omni 230 Type C_US.qxd 14.8.1 13:15 ページ a TOYOTOMI CO., LTD. Printed in Japan 5-17, Momozono-cho, Mizuho-ku, Nagoya, 467-,0855 Japan Rev. 08/14 0582000903...

Table of Contents