Download Print this page

Level List Of Equipments & Instruments Required For Production - Akai QX-3700 Service Manual

Mini hi-fi micro component system
Hide thumbs Also See for QX-3700:

Advertisement

Measurement
Specifications
Description
Frequency
- 5.0 dB ± 3.0dB
Response
- 4.0 dB ± 3.0dB
Super Bass
+ 10dB ± 3.0dB
Loudness Low
+ 6.0 dB ± 3.0dB
Equalizer
- 10.0 dB ± 3.0dB OUT
High
+ 5.0 dB ± 3.0dB
- 7.0 dB ± 3.0dB
III. Level List of Equipments & Instruments Required for Production
NO. Designation
1
Standard signal
Generator
2
AC voltmeter
3
Automatic
Distortion Meter
4
CD Player
Evaluation Filter
5
Multiplex Signal
Generator
6
Oscilloscope
7
Oscillator
8
Test Loop
9
WOW FLUTTER
METER
Measurement Condition/Method/Remarks
Test
Input
Point
Selector
SP
AUX
OUT
SP
AUX
OUT
SP
AUX
Requirement
EXT. MOD. Input
Modulation: AM 0-60%
FM 0-99.9KHz
Frequency: 0.1-140MHz
Level: -20-120dBu
Output: 1-50W
Inter Resistance 1M-10MW
Max Frequency of input signal;
5MHz
Frequency of output signal;
20Hz-20kHz
Resistance: 50
Frequency: 100KHz~30MHz
- 6 -
Input Signal
Output
Freq. Level
Level
10Hz Adjust
0dBs
100kHz
70Hz Adjust
0dBs
Adjust
0dBs
100Hz
10kHz
Reference Model
LEADER 3216
KENWOOD V7-171
VP7702C
NF3346A
KIKU SUI 3400S
KENWOOD CO-1305
KENWOOD AG-203A
LEADER LPA-070
MEGURO
MK-668G
Measurement
Vol.
Method/Remarks
MAX
Measure the level
difference from 1kHz
output
30
Measure the level
difference ( S BASS
ON)-(S BASS OFF)
at 1kHz Volume
Level 30 Position
30
Volume Level 30
Position
Remark
1 set
2 set
1 set
1 set
1 set
2 set
2 set
1 set
1 set

Hide quick links:

Advertisement

loading