Trouble shooting
The mapping panel is also very useful for troubleshooting.
Clicking the SCAN button displays a list of the Fibre
Channel port(s) and the SCSI Target devices, as well their
status (online/offline).
If a target is not detected or is listed as offline in the
STATUS field, check the device itself, the SCSI cabling, and
the SCSI termination.
Some options will be "grayed out" on the panel: they are not available because of the type of access mode or FibreBridge model or they have no effect based on other
Options
Mapping Panel
selections. The chart below shows options available based on model and access method.
Model/Access method
2200/3200
in-band
If all targets for a particular SCSI Bus are not detected or are
all listed as offline in the STATUS field, chances are the
SCSI Bus within the bridge itself has failed. Call the place
of purchase for a repair order.
If a Fibre Port is listed as offline in the STATUS field,
chances are the Fibre Port within the bridge itself has failed.
Call the place of purchase for a repair order.