R&S SMW-K550 User Manual page 18

Stream extender
Table of Contents

Advertisement

®
R&S
SMW-K550
We assume that the wanted and the interfering signals are transmitted in timeslot 1.
1. Select "Baseband C > GSM"
2. Select "Framed (Single) Configuration".
Per default, the first timeslot 0 is active.
3. To disable timeslot 0 and activate timeslot 1:
User Manual 1178.3263.02 ─ 01
How to Generate Signals for GSM AM Suppression Tests
In the frame graph, double-click slot 0.
Select "Slot Level > Off".
Double-click slot 1.
Select "Slot Level > Full".
Application Example: GSM AM Suppression Test
18