R&S SMW-K550 User Manual
R&S SMW-K550 User Manual

R&S SMW-K550 User Manual

Stream extender

Advertisement

Quick Links

®
R&S
SMW-K550
Stream Extender
User Manual
(;ÜPÍ2)
1178.3263.02 ─ 01

Advertisement

Table of Contents
loading

Summary of Contents for R&S SMW-K550

  • Page 1 ® R&S SMW-K550 Stream Extender User Manual (;ÜPÍ2) 1178.3263.02 ─ 01...
  • Page 2 This document describes the following software options: ● R&S ® SMW-K550 1413.7315.xx This manual describes firmware version FW 3.20.459.xx and later of the R&S ® SMW200A. © 2016 Rohde & Schwarz GmbH & Co. KG Mühldorfstr. 15, 81671 München, Germany...
  • Page 3: Table Of Contents

    1.3.1 Typographical Conventions.....................7 1.3.2 Conventions for Procedure Descriptions.................8 1.3.3 Notes on Screenshots.....................8 2 Welcome to the R&S SMW-K550 Option..........9 Accessing the Settings....................9 Scope........................... 10 3 Stream Extender Related Settings............. 11 4 Application Example: GSM AM Suppression Test......13 Required Options......................13 About the AM Suppression Testing................
  • Page 4: User Manual 1178.3263.02 ─ 01

    ® Contents R&S SMW-K550 User Manual 1178.3263.02 ─ 01...
  • Page 5: Preface

    1 Preface 1.1 About this Manual This user manual provides all the information specific to the option R&S SMW-K550. All general instrument functions and settings common to all applications and operating modes are described in the main R&S SMW user manual.
  • Page 6 ® Preface R&S SMW-K550 Documentation Overview ● General safety instructions, printed brochure ● Release notes, see the product page (download > firmware) ● Data sheet and brochures, see the product page (download > brochures and data sheets) ● Application notes, provided on the internet You find the user documentation on the R&S SMW product page mainly at:...
  • Page 7: Conventions Used In The Documentation

    ® Preface R&S SMW-K550 Conventions Used in the Documentation Instrument Security Procedures Deals with security issues when working with the R&S SMW in secure areas. Data Sheets and Brochures The data sheet contains the technical specifications of the R&S SMW. Brochures pro- vide an overview of the instrument and deal with the specific characteristics, see www.rohde-schwarz.com/product/SMW200A...
  • Page 8: Conventions For Procedure Descriptions

    ® Preface R&S SMW-K550 Conventions Used in the Documentation 1.3.2 Conventions for Procedure Descriptions When describing how to operate the instrument, several alternative methods may be available to perform the same task. In this case, the procedure using the touchscreen is described.
  • Page 9: Welcome To The R&S Smw-K550 Option

    Accessing the Settings 2 Welcome to the R&S SMW-K550 Option The R&S SMW-K550 is a software option that allows you to duplicate generated base- band signals (streams) for specific system configurations. By that means, four base- band streams with real-time data sources can be generated in parallel. The generated...
  • Page 10: Scope

    ® Welcome to the R&S SMW-K550 Option R&S SMW-K550 Scope 2.2 Scope Tasks (in manual or remote operation) that are also performed in the base unit in the same way are not described here. In particular, this includes: ● Managing settings and data lists, like storing and loading settings, creating and accessing data lists, or accessing files in a particular directory.
  • Page 11: Stream Extender Related Settings

    Stream Extender Related Settings R&S SMW-K550 3 Stream Extender Related Settings Duplicting streams is a feature that requires the additional option R&S SMW-K550. Access: 1. In the task bar R&S SMW, select the "System Configuration > System Configura- tion". 2. In the "Fading/Baseband Configuration" dialog, select "Mode > Advanced".
  • Page 12 Available are the standard settings and the following parameter, dedicated for the option R&S SMW-K550. Duplicate Streams ← System Configuration > Fading/Baseband Configuration (requires option R&S SMW-K550) This parameter is enabled in the configurations 3x1x1 and 4x1x1. In a 3x1x1 configuration for example, there are (per default) 3 basebands and 3 streams.
  • Page 13: Application Example: Gsm Am Suppression Test

    BS would then require two or more signal generators. Such setup can require extensive configurations and complex synchronization. In R&S SMW equipped with option R&S SMW-K550, the generation of 4 wanted and one interfering GSM signals is a straightforward solution. This section is a short intro- duction in the AM suppression testing.
  • Page 14 ® Application Example: GSM AM Suppression Test R&S SMW-K550 About the AM Suppression Testing Simplified test setup for base station receiver testing Figure 4-1 shows a simplified example of a test setup for AM suppression tests. Figure 4-1: Simplified test setup for AM suppression tests of multi-carrier BS equipped with multi-...
  • Page 15: How To Generate Signals For Gsm Am Suppression Tests

    ® Application Example: GSM AM Suppression Test R&S SMW-K550 How to Generate Signals for GSM AM Suppression Tests Within the available BS RF bandwidth, the up to 4 wanted signals are allocated sym- metrically around the center frequency. The interfering signal is sent on the center fre- quency.
  • Page 16 ® Application Example: GSM AM Suppression Test R&S SMW-K550 How to Generate Signals for GSM AM Suppression Tests Consider to load you own data lists and to configure the GSM bursts and frames according to the specification 51.021. The example assumes the following settings: ●...
  • Page 17 ® Application Example: GSM AM Suppression Test R&S SMW-K550 How to Generate Signals for GSM AM Suppression Tests The four wanted signals are routed to the RF A; the interfering signal to RF B. 3. In the status bar, set the frequency ("Freq A" and "Freq B") to the frequency of the...
  • Page 18 ® Application Example: GSM AM Suppression Test R&S SMW-K550 How to Generate Signals for GSM AM Suppression Tests We assume that the wanted and the interfering signals are transmitted in timeslot 1. 1. Select "Baseband C > GSM" 2. Select "Framed (Single) Configuration".
  • Page 19 ® Application Example: GSM AM Suppression Test R&S SMW-K550 How to Generate Signals for GSM AM Suppression Tests The default burst type is sufficient. It uses GMSK modulation and PN9 data source. ("Common > Burst Type = Normal (GMSK / Full Rate)" and "Normal (GMSK) >...
  • Page 20 ® Application Example: GSM AM Suppression Test R&S SMW-K550 How to Generate Signals for GSM AM Suppression Tests 2. In the block diagram, activate the RF outputs. The display resembles the one on the following figure. The additional information Figure 4-3 illustrates the routing and the frequency allocation of the wanted and the interfering signals.
  • Page 21: Remote Control Commands

    ® Remote Control Commands R&S SMW-K550 5 Remote Control Commands Example: Generating signals for GSM AM suppression testings The following is an example on how to select the correct system configuration and con- figure the instrument in general. Not all GSM-related settings configurations are shown.
  • Page 22 6 or 8 streams, where 4 of them can be signals with real-time data source. Parameters: <DuplicateStream> 0 | 1 | OFF | ON *RST: Example: :SCONfiguration:APPLy :SCONfiguration:MODE ADV :SCONfiguration:FADing SISO3X1X1 :SCONfiguration:DUPLicate:STReam 1 :SCONfiguration:APPLy Options: R&S SMW-K550 Manual operation: "Duplicate Streams" on page 12 User Manual 1178.3263.02 ─ 01...
  • Page 23: Glossary: 3Gpp Specifications, References, Documents With Further Information

    ® Glossary: 3GPP Specifications, References, Documents with Further Informa- R&S SMW-K550 tion Glossary: 3GPP Specifications, References, Documents with Further Information TS 51.021: " Technical Specification Group GSM/EDGE Radio Access Network; Base Station System (BSS) equipment specification; Radio aspects" User Manual 1178.3263.02 ─ 01...
  • Page 24: List Of Commands

    ® List of Commands R&S SMW-K550 List of Commands :SCONfiguration:DUPLicate[:STReam]......................22 User Manual 1178.3263.02 ─ 01...
  • Page 25: Index

    ® Index R&S SMW-K550 Index AM suppression White papers ............... 7 Test setup ..............14 AM suppression test Example assumptions ..........16 Frequency allocation ........... 15 Instrument configuration ..........16 Interferer ..............14 Setup cabling .............. 15 Test signal ..............17 Wanted signal .............

Table of Contents