Bostitch CAP1615-OF Instruction Manual page 15

Oil free portable air compressor
Table of Contents

Advertisement

Available languages

Available languages

4
Defective air tank
5
Leaking seals
6
Defective Safety Valve
(G)
7
Regulator is not adjusted
correctly for accessory
being used
8
Prolonged excessive
use of air
9
Compressor is not large
enough for accessory
10
Hole in air hose
11
Check Valve (F) restricted Contact a BOSTITCH factory service center or a BOSTITCH
12
Air leaks
13
Regulator is damaged
14
Motor overload protection
switch has tripped
15
Tank pressure exceeds
Pressure Switch (I) cut-in
pressure
16
Extension cord is wrong
length or gauge
17
Loose electrical
connections
18
Possible defective motor
19
Paint spray on internal
motor parts
20
Fuse blown, circuit
breaker tripped
21
Worn Belt
22
Restricted Air Intake
Filter (J)
Air tank must be replaced. Do not repair the leak.
Risk of bursting. Do not drill into, weld or
otherwise modify air tank or it will weaken. The air tank
can rupture or explode.
Contact a BOSTITCH factory service center or a BOSTITCH
authorized service center.
Operate Safety Valve (G) manually by pulling on ring. If
valve still leaks, it must be replaced.
It is normal for some pressure drop to occur when an
accessory is used, adjust the regulator as instructed in
Regulator
under Features if pressure drop is excessive.
NOTE:
Adjust the regulated pressure under flow conditions
while accessory is being used.
Decrease amount of air usage.
Check the accessory air requirement. If it is higher than the
CFM or pressure supplied by your air compressor, a larger
compressor is needed to operate accessory.
Replace air hose.
authorized service center.
Tighten fittings.
Replace.
Motor Overload Protection
Refer to
If motor overload protection trips frequently, contact a
BOSTITCH factory service center
or a BOSTITCH authorized service center.
Motor will start automatically when tank pressure drops
below cut-in pressure of Pressure Switch (I).
Check for proper gauge wire and cord length. Refer to the
Extension Cords paragraph in the Installation section.
Contact a BOSTITCH factory service center or a BOSTITCH
authorized service center.
Contact a BOSTITCH factory service center or a BOSTITCH
authorized service center.
Contact a BOSTITCH factory service center or a BOSTITCH
authorized service center. Do not operate the compressor in
the paint spray area.
See flammable vapor warning.
1. Check fuse box for blown fuse and replace as necessary.
Reset circuit breaker. Do not use a fuse or circuit breaker
with higher rating than that specified for our particular
branch circuit.
2. Check for proper fuse. You should use a time delay fuse.
3. Check for low voltage conditions and/or proper extension
cord.
4. Disconnect the other electrical appliances from circuit or
operate the compressor on its own branch circuit.
Contact a BOSTITCH factory service center or a BOSTITCH
authorized service center.
Clean or replace Air Intake Filter (J). Do not operate the air
compressor with the filter removed. Refer to the
paragraph in the Maintenance section.
15
under Features.
Air Filter