Syntech Information 1166 User Manual

Bluetooth wireless scanners
Hide thumbs Also See for 1166:

Advertisement

Quick Links

1166/1266 Bluetooth Wireless Scanners
User's Manual
Document Number: 1X66-2
Release Date: Dec. 2005
© 2005, SYNTECH INFORMATION Co., Ltd..
All rights reserved. CipherLab is a registered trademark of SYNTECH
INFORMATION Co., Ltd.

Table of Contents

Revision History .......................................................................................iv
Restore Default Settings ...........................................................................1
Exit Setup without Changes .....................................................................1
Set Connection...........................................................................................1
RF Auto Shutdown Duration...................................................................1
Transmit Buffer Setting ...........................................................................1
Memory Mode Parameters ......................................................................2
List Setting.................................................................................................3
Buzzer Settings ..........................................................................................3
Reading Redundancy Setting...................................................................4
Scan Mode Setting ....................................................................................4
Auto-Sense Setting ....................................................................................4
Scanner Time-out Duration .....................................................................5
Negative Barcode Setting .........................................................................5
Delay between Reread ..............................................................................5
Keyboard Wedge Parameters ..................................................................6
RS-232 Parameters ...................................................................................9
Bluetooth Serial Port Parameters..........................................................11
Bluetooth HID Parameters.....................................................................12
Prefix / Postfix Settings...........................................................................15
Character Substitution ...........................................................................15
Code ID Selection....................................................................................15
Code ID Setting .......................................................................................16
Length Code Setting (2 digits) ...............................................................17
Select Readable Codes ............................................................................20
Code39 Parameters.................................................................................25
Italy Pharmacode Parameters ...............................................................25
French Pharmacode Parameters ...........................................................26
Industrial 25 Parameters........................................................................26
Interleave 25 Parameters .......................................................................27
Matrix 25 Parameters.............................................................................29
Codabar Parameters...............................................................................30
Plessey Parameters..................................................................................31
Telepen Parameters ................................................................................31
MSI Parameters ......................................................................................32
EAN128 Parameters ...............................................................................33
EAN8 Parameters ...................................................................................34
UPCA Parameters...................................................................................34
UPCE Parameters...................................................................................35
EAN13 Parameters .................................................................................36

Advertisement

Table of Contents
loading

Summary of Contents for Syntech Information 1166

  • Page 1: Table Of Contents

    Telepen Parameters ................31 Document Number: 1X66-2 MSI Parameters ..................32 Release Date: Dec. 2005 EAN128 Parameters ................33 © 2005, SYNTECH INFORMATION Co., Ltd.. EAN8 Parameters ...................34 All rights reserved. CipherLab is a registered trademark of SYNTECH UPCA Parameters...................34 INFORMATION Co., Ltd.
  • Page 2: Revision History

    RSS Code ID Selection ................37 RSS14 Parameters ..................37 Revision History RSS Limited Parameters................38 RSS Expanded Parameters ..............38 Activate Editing Formats ...............39 Editing Format Parameters ..............40 Version Release Notes Decimal Digits ..................52 Date Hexadecimal Digits .................53 V 1.00 Oct. 31, 2005 First release.
  • Page 3: Restore Default Settings

    Restore Default Settings Memory Mode Parameters • Memory Mode Exit Setup without Changes Enable < Disable > • Clear Data Set Connection Clear Programming Instructions: (1) Read the label. (2) Read the Serial Number barcode Confirm on the bottom of the desired 3666 Base Station within 5 seconds to complete this •...
  • Page 4: List Setting

    List Setting Reading Redundancy Setting < No Redundancy > Page1 2 Times Page 6 3 Times Page 2 4 Times Page 7 Scan Mode Setting Page 3 Page 8 < Auto Off Mode > Page 4 Continuous Mode Page 9 Auto Power Off Mode Page 5 Alternate Mode...
  • Page 5: Scanner Time-Out Duration

    Scanner Time-out Duration Keyboard Wedge Parameters • Activate and Select Keyboard Type Programming Instructions: (1) Read the label. (2) Program the desired time-out duration by reading Decimal Digits on page 53. (3) Read the “Validate” label (also Programming Instructions: (1) Read the label. (2) Program the desired keyboard on page 53) to complete this setting.
  • Page 6 • Keyboard Alphabets Layout • Alphabet Transmission < Default Layout > < Case Sensitive > AZERTY Ignore Case • Digits Transmission QWERTZ • Keyboard Digits Layout < Alphanumeric Key > Numeric Key < Default Layout > • Alt Composing Lower Row Upper Row •...
  • Page 7: Rs-232 Parameters

    RS-232 Parameters • Flow Control (single port only) • Activate RS232 Interface < None > Scanner Ready • Baud Rate Data Ready INV. Data Ready 115200 • Inter-Character Delay 38400 119200 Programming Instructions: (1) Read the label. (2) Program the desired inter- <...
  • Page 8: Bluetooth Serial Port Parameters

    Bluetooth Serial Port Parameters Bluetooth HID Parameters • Activate Bluetooth Serial Port Interface • Activate and Select Keyboard Type • Device Name Broadcasting Programming Instructions: (1) Read the label. (2) Program the desired keyboard number (shown in the following table) by reading Decimal Digits on page 53.
  • Page 9 • Authentication • Keyboard Capital Lock Type < Default > < No > Shift Lock • PIN Code Capital Lock • Capital Lock Setting Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 54. One character consists of 2 Capital Lock ON hexadecimal digits.
  • Page 10: Prefix / Postfix Settings

    Prefix / Postfix Settings Code ID Setting Prefix Code * Code 39 * Postfix Code * Italy Pharmacode * Character Substitution French Pharmacode * Industrial 25 * Set 1 * Interleave 25 * Set 2 * Matrix 25 * Set 3 * Codabar * Programming Instructions: (1) Read the label.
  • Page 11: Length Code Setting (2 Digits)

    Length Code Setting (2 digits) • Matrix 25 Length Code • Code 39 Length Code Enable < Disable > Enable • Codabar Length Code < Disable > • Italy Pharmacode Length Code Enable < Disable > Enable • UPCA Length Code <...
  • Page 12: Select Readable Codes

    • Code 93 Length Code Select Readable Codes • Code 39 Enable < Disable > < Enable > • Code 128 Length Code Disable • Italy Pharmacode Enable < Disable > Enable • EAN128/RSS Length Code < Disable > • French Pharmacode Enable <...
  • Page 13 • Matrix 25 • Plessey Enable Enable < Disable > < Disable > • Codabar • Telepen < Enable > Enable Disable < Disable > • Code 93 • UPCA < Enable > < Enable No Addon > Disable Disable No Addon •...
  • Page 14 • UPCE • EAN13 < Enable No Addon > < Enable No Addon > Disable No Addon Disable No Addon Enable Addon2 Enable Addon2 < Disable Addon2 > < Disable Addon2 > Enable Addon5 Enable Addon5 < Disable Addon5 > <...
  • Page 15: Code39 Parameters

    Code39 Parameters French Pharmacode Parameters • Standard / Full ASCII Code39 • Checksum Transmission < Standard > < Enable > Full ASCII Disable • Start / Stop Transmission Industrial 25 Parameters • Start / Stop Selection Enable < Disable > <...
  • Page 16: Interleave 25 Parameters

    • Checksum Verification • Max / Min Code Length Qualification Enable Select Max / Min Length Qualification < Disable > • Checksum Transmission Max Length * Min Length * < Enable > • Fixed Code Length Qualification Disable • Max / Min Code Length Qualification Select Fixed Length Qualification Fixed Length 1 * Select Max / Min Length Qualification...
  • Page 17: Matrix 25 Parameters

    • Max / Min Code Length Qualification • Fixed Code Length Qualification Select Max / Min Length Qualification Select Fixed Length Qualification Max Length * Fixed Length 1 * Min Length * Fixed Length 2 * • Fixed Code Length Qualification Programming Instructions: (1) Read the label.
  • Page 18: Plessey Parameters

    Start / Stop Selection MSI Parameters • Checksum Verification < abcd / abcd > abcd / tn*e < Single Modulo 10 > ABCD / ABCD Double Modulo 10 ABCD / TN*E Modulo 11 & 10 • Checksum Transmission Plessey Parameters •...
  • Page 19: Ean128 Parameters

    • Fixed Code Length Qualification EAN8 Parameters • Convert to EAN13 Select Fixed Length Qualification Enable Fixed Length 1 * < Disable > • Checksum Transmission Fixed Length 2 * Programming Instructions: (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 53.
  • Page 20: Upce Parameters

    UPCE Parameters EAN13 Parameters • System Number Selection • ISBN Conversion System Number 0 and 1 Enable < System Number 0 only > < Disable > • Convert to UPCA • ISSN Conversion Enable Enable < Disable > < Disable > •...
  • Page 21: Rss Code Id Selection

    RSS Code ID Selection RSS Limited Parameters • Code ID Transmission < Enable > < ]e0 > Disable RSS14 Parameters • Application ID Transmission • Code ID Transmission < Enable > < Enable > Disable Disable • Checksum Transmission • Application ID Transmission <...
  • Page 22: Activate Editing Formats

    Activate Editing Formats Editing Format Parameters • Format 1 • Format Selection Enable Format 1 < Disable > Format 2 • Format 2 Format 3 • Restore Default Format Enable < Disable > • Format 3 Enable < Disable > •...
  • Page 23 • Applicable Data Length • Total Number of Fields Maximum Length * Minimum Length * Programming Instructions: (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 53. (3) Read the “Validate” label (also on page 53) to complete this setting.
  • Page 24 • Applicable Code Type • EAN13 No Addon Clear EAN13 Addon2 Code 39 Italy Pharmacode EAN13 Addon5 French Pharmacode UPCA No Addon Industrial 25 Interleave 25 UPCA Addon2 Matrix 25 UPCA Addon5 Codebar Code 93 Code 128 Plessey EAN128/RSS UPCE No Addon UPCE Addon2 UPCE Addon5 EAN8 No Addon...
  • Page 25 • Field1 Setting • Field2 Setting Divide Field by Divide Field by Field Terminating String Field Terminating String Field Terminating String * Field Terminating String * Programming Instructions: (1) Read the label. (2) Program the desired character Programming Instructions: (1) Read the label. (2) Program the desired string by reading Hexadecimal Digits on page54.
  • Page 26 • Field3 Setting • Field4 Setting Divide Field by Divide Field by Field Terminating String Field Terminating String Field Terminating String * Field Terminating String * Programming Instructions: (1) Read the label. (2) Program the desired Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 54.
  • Page 27 • Field5 Setting • Additional Fields Setting Divide Field by Field Terminating String Additional Field 1 * Additional Field 4 * Field Terminating String * Additional Field 2 * Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 54. One character Additional Field 5 * consists of 2 hexadecimal digits.
  • Page 28: Decimal Digits

    • Field Transmission Sequence Decimal Digits Start Field 1 Additional Field 1 Field 2 Additional Field 2 Field 3 Additional Field 3 Field 4 Additional Field 4 Field 5 • Validate Additional Field 5 Field 6 Programming Instructions: (1) Read the “Start” label. (2) Program the desired transmission sequence by reading the Field / Additional Field labels.
  • Page 29: Hexadecimal Digits

    Hexadecimal Digits Key Type < Normal > Scan Code Key Status Add Shift Add Control (L) Add Alternate (L) Add Control (R) Add Alternate (R) • Validate Update Enter Setup...
  • Page 30: Kbd Wedge Character Table

    KBD Wedge Character Table " 3 Home F5 6 Down F8 & Left Right ESC C PgUp Exec < Enter PgDn > Dly Enter* Enter* : Enter Key of the Numeric Key Pad … : Digits of Numeric Key Pad RS-232 Character Table DLE SP "...

This manual is also suitable for:

1266

Table of Contents