SERTEL ELECTRONICS
USER MANUAL
GPS RECEIVER
T-GPS-300

Advertisement

Table of Contents
loading

Summary of Contents for SERTEL T-GPS-300

  • Page 1 SERTEL ELECTRONICS USER MANUAL GPS RECEIVER T-GPS-300...
  • Page 2: Table Of Contents

    Contents ABOUT This document Operation & Maintenance, ABOUT Installation manual for Sertel GPS System. DETAILS ABSTRACT DETAILS 1) Installation Details INTRODUCTION 2) Settings details GPS ANTENNA SPECIFICATION Benefit 1 GPS RECEIVER SPECIFICATION Sertel Products are highly user-friendly device. TIME, DATE & TIME ZONE SETTING PROCEDURE...
  • Page 3: Introduction

    9. Variable Frequency Drive - Crane, Lifting, Granite cutting automation 10. Automatic Vehicle Locator Sertel is an ISO 9001:2000 certified company and is committed to the highest standards of quality. Sertel is committed towards delivering the world-class standards in engineering with its...
  • Page 4: Gps Antenna Specification

    GPS ANTENNA SPECIFICATION Model No T-GPA-014-S15 Geodetic System WGS-84 Tracking Code ‘L’ Band CA Code No. of Channel 8 Channel/ Parallel Type Helical Axial Ratio <4 dB Cable Coaxial cable 50 meter along with matching connectors. Output Connector TNC/BNC Connector Total Gain Over 42 dB Noise Figure...
  • Page 5: Gps Receiver Specification

    GPS RECEIVER SPECIFICATION Model T-GPS-300 Type Micro Controller Type Display Backlit LC Display 24 Hours Format Time Reference OCXO with stability of 1 PPM Input 1575.42 ± 1 MHz from Antenna Input Connector TNC/BNC Connector Interface TTL (Normal high) Time Stability of internal time...
  • Page 6: Time, Date & Time Zone Setting Procedure

    ---Increment the data TIME, DATE & TIME ZONE SETTING PROCEDURE FOLLOW THE BELOW STEPS FOR SETTING TIME AND DATE NOTE: Power on the unit then it displays Sertel name, after 3 seconds it will show all time related data. ENTER BUTTON...
  • Page 7  After that press Enter button then only it starts running on set time. The same procedure will be followed to change Date and Time zone. NOTE: Time zone limits from -12:30 TO +12:30 Sertel’s GPS Time Sync Server Configuration is as follows Acquisition/Tracking Specifications Initial Acquisition Time...
  • Page 8: Sertel Ntp/Sntp Configuration Procedure

    SERTEL NTP/SNTP CONFIGURATION PROCEDURE SERTEL TIME MANAGEMENT SUITE INTRODUCTION: Sertel Time Management Suite is a Sertel Network management tool. This Software allows the following  Identifying different Sertel NTP servers available in the network  Changing of IP address and network configuration.
  • Page 9 STEP2: Click the ‘Sertel IP Server Finder’ Button. A List of Sertel IPs would be displayed.
  • Page 10 STEP3: Select the required IP for viewing the IP Configuration details. The Sertel Time Management Suite also allows user to change the IP address.
  • Page 11 Automatically Sertel GPS system will restart for successful NTP configuration. We don’t need to reboot the GPS Receiver manually. On successful completion of IP configuration close the Sertel Time Management Suite and reopen it again and check the IP address.
  • Page 12 This document describes the configuration and running of the NTP time synchronization client S/W developed for Windows OS platform. This software fetches the time from any Sertel NTP server and synchronizes the local system time with it. This document describes the necessary steps to install and run the Client s/w to synchronize the server time with the local client systems.
  • Page 13 [NOTE: Admin Privileges is required to both install and run the software on the target system.] RUNNING THE Sertel NTPClient 1.2: 1. Open the NTPClient from the start menu (Start -> All Programs -> Sertel NTPClient 1.2). 2. In order to change the IP Address of the NTP server, click “Configure” button in the application and enter the new IP address of the Sertel NTP Server (IP of Sertel’s hardware...
  • Page 14 3. Click the “Start” button to start synchronizing the local system time with that of the NTP server. Note:  It is required to run the application with administrator privileges or else the application would throw an “Access Denied” error in the “Sync Status”. ...
  • Page 15: Irig Time Code Format

    The frame length of IRIG-B is 1 second long and contains 100 elements (pulse) each of which starts every 10 millisecond (un modulated) and 1 millisecond (modulated). SERTEL GPS/MASTER CLOCK provides output of IRIG-B in amplitude modulated signal (1 KHz) output at rear panel of BNC Connectors.
  • Page 16 Permissible Code Formats Format Modulation Type Carrier Frequency Coded Expressions 0,1,2 0,2,3,4,5 0,1,2,3,4,5,6,7 0,1,2 1,2,5,6 The bits are modulated on a carrier. A three-digit suffix specifies the type and frequency of the carrier, and which optional information is included: Modulation type 0.
  • Page 17: User's Manual - Safety Guide

    If the unit does not operate normally by following the operating instructions. If the unit has been dropped or the enclosure is damaged; Replacement parts - If replacement parts are required, ensure that only replacement parts recommended by the SERTEL are used. AFTER SALES SERVICE Please contact...
  • Page 18: Annexure-I

    ANNEXURE-I...