Delayed (Electric Rate and
Departure Time) : The vehicle
estimates the charging start time
based on the utility rate schedule,
utility rate preference, and the
programmed departure time for the
current day of the week. The vehicle
will charge during the least
expensive rate periods to achieve a
full battery charge by the departure
time. Electrical rate information from
the utility company for the charging
location is required for this mode.
Also, if the selected electric rate
settings result in a very long charge
completion time, the vehicle will
start charging immediately upon
plug-in. For example, if the electric
rate table is set up with all Peak
rates and the rate preference is to
charge during Off-Peak rates only,
then the vehicle will start charging
immediately upon plug-in.
Charge Limit Preference Selection
The Charge Limit Preference setting
allows the customer to select their
vehicle s charge level so it matches
the capability of their charging
location. If the vehicle consistently
stops charging after plugging in, or if
a circuit breaker continues to trip,
reducing to a lower Charge Limit
Preference may resolve the issue.
The Charge Limit Preference should
be configured to match the electrical
current rating for the electrical outlet
that the charge cord is connected
to. The Charge Limit Preference
settings are:
Maximum: Limits AC current to
12 amps
Reduced: Limits AC current to
8 amps
Exact current levels may vary from
the values shown in this manual.
Check the vehicle for the current
available levels.
Instruments and Controls
The Charge Limit Preference setting
resets to the Reduced 8 amp setting
each time the vehicle is driven.
Location Based Charging can be
enabled to maintain Maximum
12 amp setting at a specified Home
location. See Location Based
Charging later in this section.
The Charge Limit Preference setting
can be changed at any time while
the center stack display is operable.
Warning
Using a charge level that exceeds
the electrical circuit or electrical
outlet capacity may start a fire or
damage the electrical circuit. Use
the lowest charge level until a
qualified electrician inspects the
electrical circuit capacity. Use the
lowest charge level if the
electrical circuit or electrical outlet
capacity is not known.
121