6. Room Temperature Thermistor Circuit
Fig. 6-1 shows the room temperature
G
thermistor circuit.
5V
Room
temperature
thermistor
R309
R310
A
0V
7. Heat exchanger temperature thermistor circuit
The circuit detects the indoor heat
G
exchanger temperature and controls
the following.
(1) Low-temperature defrosting during
cooling
and
operation.
The voltage at A depends on the heat
exchanger temperature as shown in
Fig. 7-2.
0305E Pg 57-82
Micro
computer
Room
64
temp. input
C302
0V
Fig. 6-1
5V
Heat exchanger
temperature thermistor
R307
R308
A
0V
Fig. 7-1
dehumidifying
62
The voltage at A depends on the room
G
temperature as shown in Fig. 6-2.
5
4
3
2
1
0
0
10
Fig. 6-2
Micro computer
Heat
63
exchanger
C301
temperature
input
0V
5
4
3
2
1
0
0
10
-10
Fig. 7-2
– 62 –
4/1/06, 10:59 AM
20
30
40
20
30
40

Hide quick links: