Philips 32PFL3403D/85 Service Manual page 32

Hide thumbs Also See for 32PFL3403D/85:
Table of Contents

Advertisement

EN 32
5.
LC8.1U LA
5.7.3
Content and Usage of the One-Zip Software File
Below you find a content explanation of the One-Zip file, and
instructions on how and when to use it.
Ambi_clustername_version.zip. Not to be used by
Service technicians.
Panel_clustername_version.zip. Not to be used by
Service technicians.
EDID_clustername_version.zip. Contains the EDID
content of the different EDID NVMs. See ComPair for
further instructions.
FUS_clustername_version.zip. Contains the
"autorun.upg" which is needed to upgrade the TV main
software and the software download application.
ProcessNVM_clustername_version.zip. Default NVM
content. Must be programmed via ComPair.
5.7.4
How to Copy NVM Data to/from USB
Write NVM data to USB
1. Insert the USB stick into the USB slot while in SAM mode.
2. Execute the command "Copy to USB", to copy the NVM
data to the USB stick. The NVM filename on the USB stick
will be named "NVM2USB.bin" (this takes a couple of
seconds).
Write NVM data to TV
1. First, rename the filename (via a PC) on the USB stick to
"USB2NVM.bin".
2. Insert the USB stick into the USB slot while in SAM mode.
3. Execute the command "Copy from USB" to copy the USB
data to NVM (this takes about a minute to complete).
Important: The file must be located in the root directory of the
USB stick.