Download Print this page

Nuvo Koolspace 250 Assembly & Operation Manual

Nuvo wine cellar assembly & operation manual 250/500

Advertisement

Quick Links

nuvo
2 5 0 / 5 0 0
CE LLAR
TM
k o o l s p ac e
ASSEMBLY & OPERATION MANUAL
~1~

Advertisement

loading

Summary of Contents for Nuvo Koolspace 250

  • Page 1 2 5 0 / 5 0 0 CE LLAR k o o l s p ac e ASSEMBLY & OPERATION MANUAL...
  • Page 2 1. LOCATING YOUR WINE CELLAR - Remember, it is not an appliance, it is a piece of furniture Provide 4” minimum clearance for both sides and back, keep the top completely clear. Under no circumstances should the unit be “built-in” in any way. Never locate your wine cellar outdoors or in an area with extremes of temperature and humidity.
  • Page 3: Hardware Kit

    Cam Cap Hex bolt x 26 (x30)* x 22 (x30)* Cam Pin x 24 (x28)* x 24 (x28)* In Cooling Unit Box Hex Bolt (Flange) *NOTE : Hardware quantities for Model 500 are indicated in parenthesis. Coupler screw Coupler hanger Panel Insulation Strip Hex wrench Hinge...
  • Page 4: Step 1 : Panel Preparation

    CAUTION : 1. Watch for sharp staples on boxes. 2. DO NOT STEP ON PANELS 3. The manual will give a recommended order to open boxes, it saves time and space. Open Boxes VP6 and VP7. Install INSULATION STRIP (J) to Back, Top, and Bottom Panels.
  • Page 5: Step 2 : Cabinet Assembly

    PANEL EDGE CAM in LOCKED POSITION Use allen key provided or #3 phillips screwdriver. Attach TOP and Bottom to Back by CAREFULLY aligning edge holes over Cam Pins and gently push together to avoid damaging cam pins. DO NOT BANG OR SLAP PANELS TOGETHER!!! Insert Cam, push all the way in under panel level (may...
  • Page 6 STEP 2 : CABINET ASSEMBLY CONTINUED Open Box VP5 or VP2. Insert Cam Pins (F) in BACK PANEL’S predrilled holes down to TAB. (May require some force) Attach SIDES to Back/Bottom/Top by CAREFULLY aligning edge holes over Cam Pins and gently push together to avoid damaging cam pins.
  • Page 7 STEP 3 : HINGE,BASE AND LEGS INSTALLATION Open Box VP3. Fasten one HINGE (found in door box) to the SIDE of the cabinet Install four LEGS (H) into BASES fully in. Fasten FRONT BASE the BOTTOM of the cabinet (FRONT BASE has to be set with end tabs away from front edge) Fasten BASE with HEX BOLTS...
  • Page 8 Install COUPLER SHELVES between the VERTICAL COUPLER and the BACK PANEL, hook them on the COUPLER HANGERS (G) Install 4 HANGERS STRIPS, hook- ing them to the COUPLER SHELVES through square holes. (Watch for orientation, all hooks have to point upwards).
  • Page 9 STEP 5 : COOLING UNIT INSTALLATION GET HELP BEFORE INSTALLING AND KEEP CHILDREN CLEAR OF CELLAR CONSTRUCTION AREA. Get helper to help guide unit, keep light cord clear of edge inside cellar and to prevent tipping of cellar. MAKE SURE INSULATION STRIP IS IN CORRECT ORIENTATION. Run light cord through Cut-out. Slide unit into the back opening by angling unit A to allow light cord to clear and straighten to push in B .
  • Page 10 STEP 6 : LIGHT AND LIGHT COVER INSTALLATION Remove plastic CAP at right end for only LIGHT , DO NOT remove CAP from LIGHT Insert LIGHT to LIGHT COVER C A P LIGHT Cord behind ~10~ Plug cord to LIGHTS LIGHT Insert LIGHT COVER to holes pre drilled on front edge of TOP panel.
  • Page 11 DOORS Insert onto BOTTOM HINGES Install TOP HINGES with HEX BOLTS (B) NOTE : ~11~ 4 4 4 Adjust fi nal position of the door before tightening the bolts and move cellar into place, leaving 4” clearance all around cellar. MAKE SURE CABINET IS AIRTIGHT! Adjust level...
  • Page 12 CONTROLS : FEATURES: - Default SET temperature 57º F/14º C (ideal for wine storage). - Calibration option of the temperature sensor. - Display of actual temperature by request. - SET temperature range 52ºF-64ºF. - Digital temperature sensor. - Dual display Fº/Cº. - Settings are stored in memory for power failures.
  • Page 13 Never stack bottles more than two rows high on a shelf; all shelves must be installed as directed. Avoid placing bottles directly in front of the cooling unit’s circulating fan for more uniform temperature in cabinet. MODEL 250 Max 4" dia. bottles 3.5"...
  • Page 14: Troubleshooting Guide

    Although each Vintage Keeper cooling unit has been carefully tested at every stage of manufacture, occasional problems arise, the majority of which are due to rough or careless handling during shipping or installation. Other problems may derive from improper cabinet assembly, power interruption or surge, low line voltage (less than your unit rating of 105V or 240V), or failure to clean the unit regularly (see illustration below).
  • Page 15 LIMITED WARRANTY AND PRODUCT SUPPORT ONE YEAR LIMITED WARRANTY If your Koolspace cooling unit or cabinet fails to perform as designed within one year of the date of purchase, VINTAGE KEEPER INC. warrants that, upon your request, it will be repaired or replaced, at our option, during the one year warranty period. This warranty applies only to the first end-user purchaser of a Koolspace unit that is purchased and used in the continental United States or Canada (excludes Alaska and Hawaii).
  • Page 16 2 5 0 / 5 0 0 C EL LAR k o o l s p ac e Toll free: 1-888-274-8813 www.koolspace.com ~16~...

This manual is also suitable for:

Koolspace 500