Condenser Fan Error (E CF)
1
Reset the unit and
Input Test1 Mode.
(Push the button 1 time)
2
Check the fan rotating.
Does fan rotate?
Fan Motor
Yes
Go to 4
3
Check the Fan motor.
Rotate fan using hand.
It feel sticky?
Fan Motor
No
Go to 3
Change the
Yes
Fan motor
- 43 -
4
Check the Fan Motor voltage
Is Fan Motor voltage 8~12V?
TEST MODE 1
CON7
4
th
pin ~ 6
th
pin
Yes
5
Check the Fan Motor voltage
Is Fan Feed Back voltage 0V, 5V?
TEST MODE 1
CON7
2
pin ~ 6
pin
nd
th
No
6
Explain to customer
Replace
No
Main PCB
CON7
Voltage [V]
8~12V
Change the
Yes
motor
CON7
Voltage [V]
Not 0V, 5V