Advertisement

Available languages

Available languages

Quick Links

georg neumann gmbh · leipziger str. 112 · 10117 berlin · germany
tel +49 (0)30 / 41 77 24-0 · fax -50 · headoffice@neumann.com · www.neumann.com
KMR 81 D
Bedienungsanleitung
Operating Manual
Registrieren Sie bitte Ihr
System auf der Website
www.my-Solution-D.com,
um über Updates informiert
zu werden!
Please register your system
on the website
www.my-Solution-D.com,
to be informed whenever updates
are available!
2
8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KMR 81 D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Neumann KMR 81 D

  • Page 1 Please register your system on the website www.my-Solution-D.com, to be informed whenever updates are available! georg neumann gmbh · leipziger str. 112 · 10117 berlin · germany tel +49 (0)30 / 41 77 24-0 · fax -50 · headoffice@neumann.com · www.neumann.com...
  • Page 2 Einleitung schlossen wird. Das KMR 81 D ist gegen Überspan- nung geschützt und verträgt kurzzeitig bis +55 V. In dieser Anleitung fi nden Sie alle wichtigen In- Reparatur- und Servicearbeiten dürfen nur von formationen für den Betrieb und die Pfl ege der erfahrenem und autorisiertem Fachpersonal von Ihnen erworbenen Produkte.
  • Page 3 Signalverarbeitung bietet das mit dem AES42-Mikrofoneingang Ihres Digitalen Mikrofon außerdem Funktionen, die bisher nur Mikrofon-Interface DMI, des Neumann Connec- im Mischpult oder zusätzlichen Geräten realisiert tion Kits oder eines anderweitigen Audiogerätes werden konnten. Diese Funktionen werden im Ka- nach AES42.
  • Page 4 Parameter sind einstellbar. richtungen lieferbar (siehe auch Kapitel Zubehör). Abb. 1 = KMR 81 D nx WS 81 = KMR 81 D nx + Abb.2 = KMR 81 D nx Windschutzkorb = KMR 81 D nx + Windschutzkorb + Windjammer...
  • Page 5: Technische Daten

    Verringern Sie vor der Außerbetriebnahme und Dynamikumfang, A-bewertet : ....114 dB dem Abziehen von Kabeln den Lautstärkepegel Ihres weiterverarbeitenden Gerätes. A/D-Wandlung ......Neumann-Verfahren Ziehen Sie beim Lösen von Kabeln stets nur an (patentiert), 28 Bit den Steckverbindern und nicht am Kabel. interne Wortbreite Mikrofone, die nicht im Einsatz sind, sollte man Digitale Signalverarbeitung..Fixpoint, variable...
  • Page 6: Fernsteuerbare Funktionen

    (bezogen auf eine Pegeländerung von ca. 10 dB ) * Ausführliche Beschreibungen und weitere Artikel fi nden Sie Peak-Limiter ..........On/Off in unserem Zubehörkatalog oder unter www.neumann.com Attack time ........–160 μs (negativ) Release time ......ca. 50 ms...150 ms (signalabhängig) Threshold ........Off : 0 dBFS fest...
  • Page 7 Lieferumfang Mikrofon Mikrofon KMR 81 D nx Windschutz WS 81 Drehpack Bedienungsanleitung Fehlercheckliste ▶ ▶ Fehler Mögliche Ursachen Abhilfe Keine Speisespannung fehlt Überprüfen Sie das Speisegerät und ggf. die Funktion / zugehörigen Soft ware-Einstellungen Keine Signal- (RCS -> System -> MicPWR).
  • Page 8: Safety Instructions

    RCS can be found in Brief description the Download section as well. The KMR 81 D digital microphone is a condenser Additional information concerning the digital microphone of the Solution-D family with a digital...
  • Page 9 Ensure that the microphone and all equipment in the digital signal chain are synchronized. If the Extremely low-frequency signals can result from Neumann Digital Microphone Interface is used, interference such as structure-borne noise or pop the connected microphones should always be and wind noise.
  • Page 10 The soft ware in the microphone can be updated analog processing. via the Neumann DMI. Therefore future soft ware enhancements will also be available to existing Peak limiter: The very fast peak limiter has an ad- customers.
  • Page 11: Shutdown And Storage

    ...... 141 dB SPL the connector and not on the cable itself. Microphones which are not in use should not be A/D conversion ......Neumann process allowed to remain on the stand gathering dust. A (patented), 28-bit microphone which is unused for a prolonged pe-...
  • Page 12: Remote Controlled Functions

    Peak limiter ........... On/Off * Detailed descriptions and additional articles can be found Attack time .........–160 μs (negative) in our accessories catalog or at: www.neumann.com Release time ....Approx. 50 ms to 150 ms (signal-dependent) Threshold ........Off : 0 dBFS fi xed On: –15 dBFS to 0 dBFS,...
  • Page 13: Scope Of Delivery

    Scope of delivery Microphone KMR 81 D nx microphone WS 81 windscreen Twist pack Operating manual Troubleshooting ▶ ▶ Problem Possible causes Solution Microphone not Supply voltage not activated Check the power supply device and if necessary operating / the associated soft ware settings (RCS -> System ->...
  • Page 14 10. Frequenz- und Polardiagramme 10. Frequency responses and polar patterns gemessen im freien Schallfeld nach IEC 60268-4, Toleranz ±2 dB measured in free-fi eld conditions (IEC 60268-4), tolerance ±2 dB...
  • Page 15 Connection Kit AES/EBU Connection Kit S/PDIF Interface DMI-2 portable Interface DMI-8 EA 2124 A mt MNV 21 mt SG 21 bk WKE 81 Set WS 81...
  • Page 16 Limitation of Liability Declaration of Conformity Georg Neumann GmbH shall not be liable for consequences of an inappro- Georg Neumann GmbH hereby declares that this device conforms to priate use of the product not being in compliance with the technical allow- the applicable CE standards and regulations.

Table of Contents