NorthStar 10 kW Installation Manual page 25

Northstar navigation northstar 10 kw radar installation manual
Table of Contents

Advertisement

You can connect the radar processor to either the Northstar 6100i OR to the Northstar 8000i, but not
to both simultaneously.
10 kW radar processor interface connectors
Connector name
Network
Power (+Ve and -Ve)
NMEA / Comms
Scanner
Chassis Earth
3.10.3.5 Earth the 10 kW scanner
The Earth bolt MUST be connected to the vessel's ground system.
Connect one end of the copper Earth plate (2) to the bolt (1) on the scanner. Connect the other end of
the Earth plate to the mounting location using the Earth bolt (3).
Northstar 10 kW Radar Installation Manual
Connector function
Ethernet communications for
the 8000i
Power input
Data communications (for the
6000i and 6100i systems
only)
Remote power control, relay
and ignition (for the 6000i,
6100i, and 8000i)
NMEA communications for
compass (for the 8000i only).
Scanner communications
Grounding point
Connects to...
8000i network, using the 8000i
network cable (NS00481X)
Ship's power 24 V DC ONLY (using
the power cable)
6000i or 6100i display unit, using
radar communications cable
(NS003107/NS003108)
6000i, 6100i, or 8000i remote
power signals, relay or ignition;
cable not supplied
8000i NMEA compliant compass;
cable not supplied
Scanner, using the
interconnection cable (NS003105
or NS003106)
Vessel's Ground using ground
wire
25

Advertisement

Table of Contents
loading

Table of Contents